User Manual for BM Refrigerators Beverage-Air
Rev. 08/20 Beverage-Air 5
PRODUCT INFO CLEARANCE AND PLACEMENT
Placement
Consider the following when selecting a location for your Refrigerator:
Clearance:
None required at top, back or sides. 5 1/8 inches below.
Floor Load: the oor on which the Refrigerator is located must be even and level, free from vibrations, and strong enough
to support the combined weights of the unit and maximum product load.
Ventilation: Grille area at front must be free and clear of any object or wall.
Power Outlet: Dedicated power outlet is located within the length of the unit's power cord.
CLEARANCE
Model
Cabinet Dimensions
w x d x h (Inches)
Door
Count
Glass or
Solid Door
Full Load
Amps
Power Cord
Plug (NEMA)
Refrigerant Type /
Charge (g) / (oz)
BM23HC 24 x 30 1/8 x 53 1 Solid 2 5-15P R-290 / 55 / 1.94
BM23HC-B-28* 24 x 30 1/8 x 39 3/8 1 Solid 2 5-15P R-290 / 55 / 1.94
Height includes casters
* No Tap
All models will maintain product temperature between 35.5 and 40.5 degrees F. at the factory setting of 38.
0
F.
All models are 115 volts, 60 Hz AC.
ALWAYS REFERENCE YOUR EQUIPMENT DATA PLATE AMPS, REFRIGERANT AND REFRIGERANT CHARGE FOR THE
MOST UP TO DATE AND ACCURATE VALUES.
There are no access valves on the refrigeration system.