D812865 00100_04
40 - RIGEL 6
INSTALLATION MANUAL
2) GENERAL INFORMATION
The RIGEL 6 control panel comes with standard factory settings. Any change
must be made using the programmer with built-in display or universal handheld
programmer.
The Control unit completely supports the EELINK protocol.
Its main features are:
- Check of 1 or 2 single-phase motors tted with thermostat
- Control of 1 or 2 single phase motors
Note: 2 motors of the same type must be used.
- Opening/closing limit switch control inputs, separate for each motor
- Separate inputs for safety devices
- Time band management
- Integrated obstacle detection
- Motor pre-heating with integrated sensor reading
- Adjustable electrodynamic braking
- Approach speed slow-down
- Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer’s job on site easier.
The jumpers concern terminals: 41-42, 41-43, 41-44, 41-45, 70-71, 70-72,
70-74, 76-77, 76-79, 81-82, 81-84. If the above-mentioned terminals are
being used, remove the relevant jumpers.
TESTING
The RIGEL 6 panel controls (checks) the run relays, triacs and safety devices (pho-
tocells and edges), before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
ATTENTION! if the leaf is installed in a public area or if an automatic operating
mode is enabled, we recommend a pair of photocells is installed at a height of 5
cm together with another pair at a height of 40-50 cm. Automatic mode means any
control not voluntarily activated by the user (example: TCA function, chrono, etc.)
3) TECHNICAL SPECIFICATIONS
Power supply 220-230V 50/60Hz(*)
Low voltage/mains insulation > 2MOhm 500V
Dielectric rigidity mains/LV 3750V~ for 1 minute
Accessories power supply
24V~ (demand max. 1A)
24V~safe
AUX 0
NO 220-230V~ (
80W MAX)
powered contact
AUX0+
AUX1+
AUX2=
80W MAX
AUX 1
NO 220-230V~ (
80W MAX)
powered contact
AUX 2
NO contact
(MAX 220-230V~ 80W)
AUX 3 NO contact (Max 24V~) 10W MAX
LOCK
Output for 12V
sole-
noid lock:
10W MAX
Dimensions
see Fig. B
Fuses see Fig. C
N° of combinations 4 billion
Max.n° of transmitters that
can be memorized
63
(*other voltages to order)
Use cycle continuous continuous 1 min. ON/
2 min. OFF
1 min. ON/
2 min. OFF
Operating
temperature range
-20°C/+50°C -20°C/+55°C -20°C/+50°C -20°C/+55°C
Maximum motor
power 220-230V
2x375 W
1x750 W
2x250 W
1x500 W
2x650 W
1x750 W
2x500 W
1x750 W
Maximum motor
power110-120V
2x320 W
1x390 W
M1+M2+AUX0+AUX1+AUX2+AUX3+LOCK= 1300W MAX T=+50°C
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
4) TUBE ARRANGEMENT Fi g. A
5) TERMINAL BOARD WIRING Fig. C
WARNINGS - When performing wiring and installation, refer to the standards in
force and, whatever the case, apply good practice principles.
Wires carrying dierent voltages must be kept physically separate from each other,
or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
Terminal Denition Description
Power
supply
L LINE
Single-phase power supply
220-230V 50/60Hz(*)
N NEUTRAL
GND EARTH
Motor
10 MOT1 RUN
Connection motor 1. Time lag during closing.11 MOT 1 COM
12 MOT1 RUN
14 MOT2 RUN
Connection motor 2. Time lag during opening.
Note: if 1 MOT.ON. = 1 do not connect any wires to terminals 14-15-16
15 MOT 2 COM
16 MOT2 RUN
Aux
20
AUX 1 - 220-230V~
POWERED CONTACT
AUX 0 congurable output - Default setting FLASHING LIGHT.
MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/
GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT AND MAINTE-
NANCE / GATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to AUX output conguration table.
21
22
AUX 1 - 220-230V~
POWERED CONTACT
AUX 1 congurable output - Default setting ZONE LIGHT Output.
MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/
GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT AND MAINTE-
NANCE / GATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to AUX output conguration table.
23
24
AUX 2 - FREE CONTACT
(N.O.)
AUX 2 congurable output - Default setting SCA GATE OPEN LIGHT Output.
MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/
GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT AND MAINTE-
NANCE / GATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to AUX output conguration table.
25
26
AUX 3 - FREE CONTACT
(N.O.)
AUX 3 congurable output - Default setting MONOSTABLE RADIO CHANNEL Output.
MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/
GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT AND MAINTE-
NANCE / GATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to AUX output conguration table.
27
28
LOCK 12V
Type of lock logic= 0 - 12V solenoid latch output.
Output activated with a pulse each time gate is opened or closed
(MODEL ECB)
29
Type of lock logic= 1 - 12V magnetic lock output.
Output activated when gate is closed or closing
Limit switch
40 Not used
41 + REF SWE Limit switch common
42 SWC 1 Motor 1 closing limit switch SWC1 (N.C.).
43 SWO 1 Motor 1 opening limit switch SWO1 (N.C.).
44 SWC 2 Motor 2 closing limit switch SWC2 (N.C.).
45 SWO 2 Motor 2 opening limit switch SWO2 (N.C.).
Accessories
power
supply
50 24V-
Accessories power supply output.
51 24V+
52 24 Vsafe+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.