TABLE “A” PARAMETERS MENU - PARA
Parameter min. max. Default
Personal
Denition Description
vork. t.
ot.1
3.0 180.0 60.0
Operation time
motor 1 [s]
Sets the value of motor 1 / 2 work time in seconds
At the end of an autoset it is set with the actual motor work value
vork. t. ot.2
3.0 180.0 60.0
Operation time
motor 2 [s]
PARTIAL
OPENING
3 90 6 Partial opening M1 [s] Time of partial opening following the activation of motor M1 PED pedestrian control
OPEN DELAY
TI E
0 10 3
Motor 2 opening delay
time [s]
Motor 2 opening delay time with respect to motor 1.
CLS DELAY
TI E
0 25 3 Motor 1 closing delay time [s] Motor 1 closing delay time with respect to motor 2.
slov -
dovn t.
ot.1
0 30 0
Slow-down time
motor 1 [s]
Sets the approach slow-down time. The slow-down time is subtracted from the work time.
NOTE: Use this function only if a limit switch is installed.
NOTE: Do not use with hydraulic motors. (***)
slov -
dovn t. ot.2
0 30 0
Slow-down time
motor 2 [s]
TCA
0 120 10 Automatic closing time [s] Waiting time before automatic closing.
TRF.LGHT.CLR.T
1 180 40
Time-to-clear trac light
zone [s]
Time-to-clear for the zone run through by trac controlled by the trac light.
output time
1 240 10
Activation time of the timed
output [s]
Activation length of timed radio channel output in seconds
OP.FORCE
1 99 50 Leaf force during opening [%]
Force exerted by leaf/leaves during opening.
Represents the percentage of force delivered at speed in comparison with the
maximum value.
WARNING: It aects impact force directly: make sure that current safety
requirements are met with the set value (*).
If necessary, install anti-crushing safety devices (**).
(***)
CLS.FORCE
1 99 50 Leaf force during closing [%]
Force exerted by leaf/leaves during closing.
Represents the percentage of force delivered at speed in comparison with the maxi-
mum value.
WARNING: It aects impact force directly: make sure that current safety
requirements are met with the set value (*).
If necessary, install anti-crushing safety devices (**).
(***)
slwd.force
1 99 50
Forza motori
in rallentamento
[%]
Force exerted by leaf / and slowdown.
It represents the percentage of power supplied to slow down.
WARNING: It aects impact force directly: make sure that current safety
requirements are met with the set value (*).
If necessary, install anti-crushing safety devices (**).
(***)
brake
0 99 0
Braking
[%]
Set the braking value from 0% (min.) to 99% (max.) according to the gate weight and
the mechanical demands involved.
e er. brake
0 99 60
Emergency braking
[%]
Sets the value between 0% (min.) and 99% (max.) of emergency braking, that is
performed by activating the safety controls present at the inputs congured as BAR
safety edge.
preheat.
0 99 30
Preheating
[%]
Set the percentage value of the current from 0 (deactivated pre-heating) to 99% which
can be made to pass through the motor windings to keep them at the right temperature.
NOTE: the NTC temperature sensor must be connected
The sensor must be placed and xed in contact with the motor to detect the outside
temperature
obst.sens.
0 99 0 Obstacle sensitivity
It allows activating obstacle detection.
The function is disabled when the parameter is set to 0, setting the value between 1 and
the maximum value, obstacle sensitivity can be increased (max value = max sensitivity).
It works only with the limit switches.
ATTENTION: This obstacle detection function does not guarantee com-
pliance with the safety regulations in force (*). To comply with the current safety
regulations, install adequate anti-crushing safety devices (**).
ATTENTION: The system detects the obstacle only if the leaf is stopped; no
obstacles breaking the leaf without managing to stop it are detected.
Detection takes place only if the leaf meeting the obstacle is moving at normal
speed. The obstacle is not detected during slow-down.
(***)
Maintenance
0 250 0
Programming number of
operations for maintenance
threshold
[in hundreds]
Allows you to set a number of operations after which the need for maintenance will
be reported on the AUX output congured as Maintenance or Flashing Light and
Maintenance .
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) The impact forces must be limited using active coasts comply with EN12978
(***)
CAUTION: After a parameter change will need to run an autoset function if the “obstacle sensitivity” is active.