Logic Denition
Default
Cross out
setting
used
Optional extras
SAFE 2
Conguration of
safety input SAFE 2.
74
6
3
Input congured as Phot op test (tested photocell active during opening only).
4 Input congured as Phot cl (photocell active during closing only).
SAFE 3
Conguration of
safety input SAFE 3.
77
2
5 Input congured as Phot cl test (tested photocell active during closing only).
6 Input congured as Bar, safety edge.
SAFE 4
Conguration of
safety input SAFE 4.
79
4
7 Input congured as Bar, tested safety edge.
8 Input congured as Bar 8k2 (Inactive on SAFE 3,4,5,6).
SAFE 5
Conguration of
safety input SAFE 4.
79
0
9
Input congured as Bar OP, safety edge with inversion active only while opening. If while closing, the
movement stops.
10
Input congured as Bar OP TEST, safety edge tested with inversion active only while opening. If while
closing, the movement stops.
SAFE 6
Conguration of
safety input SAFE 6.
84
6
11
Input congured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the
movement stops.
(Inactive on SAFE 3,4,5,6).
12
Input congured as Bar CL, safety edge with inversion active only while closing. If while opening, the
movement stops.
13
Input congured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening,
the movement stops.
14
Input congured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the
movement stops.
(Inactive on SAFE 3,4,5,6).
IC 1
Conguration of
command input IC 1.
61
0
0 Input congured as Start E.
1 Input congured as Start I.
IC 2
Conguration of
command input IC 2.
62
4
2 Input congured as Open.
3 Input congured as Close.
IC 3
Conguration of
command input IC 3.
64
2
4 Input congured as Ped.
5 Input congured as Timer.
IC 4
Conguration of
command input IC 4.
65
3 6 Input congured as Timer Pedestrian.
1ch
Conguration of the
1st radio channel
command
0
0 Radio control congured as START E.
1 Radio control congured as Start I.
2 Radio control congured as Open.
2ch
Conguration of the
2nd radio channel
command
9
3 Radio control congured as Close
4 Radio control congured as Ped
5 Radio control congured as STOP
6 Radio control congured as AUX0 **
3 ch
Conguration of the
3rd radio channel
command
2
7 Radio control congured as AUX1 **
8 Radio control congured as AUX2 **
9 Radio control congured as AUX3 **
4 ch
Conguration of the
4th radio channel
command
5
10 Radio control congured as EXPO1 **
11 Radio control congured as EXPO2 **
AUX 0
Conguration of
AUX 0 output. 20-21
6
0 Output congured as monostable Radio Channel.
1 Output congured as SCA (gate open light).
2 Output congured as Courtesy Light command.
AUX 1
Conguration of
AUX 1 output.
22-23
3
3 Output congured as Zone Light command.
4 Output congured as Stair Light
5 Output congured as Alarm
AUX 2
Conguration of
AUX 2 output.
24-25
1
6 Output congured as Flashing light
7 Output congured as Latch
8 Output congured as Magnetic lock
AUX 3
Conguration of
AUX 3 output.
26-37
0
9 Output congured as Maintenance
10 Output congured as Flashing Light and Maintenance.
11 Not used
12 Not used
13 Output congured as Gate Status
14 Output congured as Bistable Radio Channel
15 Output congured as timed Radio Channel
LOCK
Type of lock.
28-29
0
0
Output congured as 12V
solenoid latch.
1
Output congured as 12V
magnetic lock.
FIXED CODE
Fixed code 0
0
Receiver is congured for operation in rolling-code mode.
Fixed-Code Clones are not accepted.
1
Receiver is congured for operation in xed-code mode.
Fixed-Code Clones are accepted.