EasyManua.ls Logo

BidetMate BM-6000 - IMPORTANT SAFEGUARDS; General Safety Precautions; Grounding Instructions

BidetMate BM-6000
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IMPORTANT SAFEGUARDS
When using electrical products, especially when children are present, basic safety
precautions shouldalways be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING
WARNING– To reduce the risk of burns, electrocution, fire, or injury to persons.
1. Close supervision is necessary when this product is used by, on, or near children or i
nvalids.
2. Use this product only for its intended use as described in this manual. Do not use
attachments not recommended by the manufacturer.
3. Never operate this product if it has a damaged cord or plug, if it is not working properly,
if it has been dropped or damaged, or dropped into water. Return the product to a service
center for examination and repair.
4. Keep the cord away from heated surfaces.
5. Never block the air openings of the product or place it on a soft surface, such as a bed
or couch, where the air openings may be blocked. Keep the air openings free of lint, hair,
and the like.
6. Never use while sleeping or drowsy.
7. Never drop or insert any object into any opening or hose.
8. Do not use outdoors or operate where aerosol (spray) products are being used or
where oxygen is being administered.
10. Connect this product to a properly grounded outlet only. See Grounding Instructions.
SAVE THESE INSTRUCTIONS
GROUNDING INSTRUCTIONS
This product should be grounded. In the event of an electrical short circuit, grounding
reduces the risk of electric shock by providing an escape wire for the electric current. This
product is equipped with a cord having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed and grounded.
DANGER– Improper use of the grounding plug can result in a risk of electric shock.
If repair or replacement of the cord or plug is necessary, do not connect the grounding
wire to either flat blade terminal. The wire with insulation having an outer surface that is
green with or without yellow stripes is the grounding wire.
Check with a qualified electrician or serviceman if the grounding instructions are not
completely understood, or if in doubt as to whether the product is properly grounded.
This product is factory equipped with a specific electric cord and plug to permit connection
to a proper electric circuit. Make sure that the product is connected to an outlet having the
same configuration as the plug. No adapter should be used with this product. Do not
modify the plug provided — if it will not fit the outlet, have the proper outlet installed by a
qualified electrician. If the product must be reconnected for use on a different type of
electric circuit, the reconnection should be made by qualified service personnel.
If it is necessary to use an extension cord, use only a three wire extension cord that has a
three-blade grounding plug, and a three-slot receptacle that will accept the plug on the
product.Replace or repair a damaged cord.
BidetMate.com Info@BidetMate.com

Other manuals for BidetMate BM-6000

Related product manuals