OTHER ITEMS
The following items are not belong to warranty scope.
1. It can not be demolished.
2. The damage caused by wrong installation or operation.
3. Shell is broken when display is out of the factory.
4. Wire is broken.
5. Force disaster (such as fire, earthquake, etc.) or natural
disasters like lightning, etc caused by fault or damage.
6. Beyond Warranty period.
ERROR CODE TABLE
The error code is corresponding with the fault definition.
Error code
definition
0
normal
1
Current error or MOS damaged
2
Throttle error(Start detection)
3
motor no phase position
4
Hall error
5
Brake error(Start detection)
6
Under voltage
7
Motor stalling
8
communication controller receiving error
9
communication display receiving error