EasyManua.ls Logo

Binary B-540-EXT-230-RS - 6.3. RS-232 Control Connections

Binary B-540-EXT-230-RS
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
6.3. RS-232 Control Connections
Bidirectional RS-232 signals are transmitted between the device transmitter and receiver over
the category cable. The transmitter may be connected to a control system, and the receiver
may be connected to an RS-232 controllable device.
RS-232 LINK
DTE
DCE
ON
SERVICE
5 3 2
HDBaseT
1 2
ON
RS-232 LINK
DTE
DCE
ON
SERVICE
5 3 2
HDBaseT
1 2
ON
1 2
ON
RS-232 LINK
DTE
DCE
ON
SERVICE
5 3 2
HDBaseT
1 2
ON
A A BB
RS-232 Control (DB-9)- See Section 6.3.1
HDBaseT Link category - See Section 6.1
FIGURE 9: RS-232 Connections
6.3.1. RS-232 Control (DB-9) Connection
Bidirectional RS-232 signals are transmitted between the B-540-EXT-230-RS Transmitter
and Receiver over the Cat 5e/6 cable. The transmitter may be connected to a control system
controller and the Receiver connected to an RS-232 controllable device.
PIN FUNCTION
2 RxD (Data Receive)
3 TxD (Data Transmit)
5 GND
PIN FUNCTION
2 TxD (Data Transmit)
3 RxD (Data Receive)
5 GND
235
DTE
DCE
ON
SERVICE
1 2
ON
ON
SERVICE
1 2
ON
DTE
DCE
FIGURE 10: RS-232 Modes and Connections
B-540-EXT-230-RS Transmitter
RS-232 Controllable
Device
Control
System
B-540-EXT-230-RS Receiver
DTE Mode
DTE (Down)
RS-232 DB-9 Pinouts
DCE Mode
DCE (Up)

Related product manuals