EN
0.1
1.09 A
Rated Motor Power Factor 0.71
Rated Motor Efficiency 64.4%
Seconds
Standards relating to the connection and use of electrical apparatus in hazardous areas must be taken into
consideration.
Only trained personnel familiar with these standards should handle this type of apparatus.
Value
Maximum Hz Output
400 V
Rated Motor Speed 1380 RPM
Electric Motor
Rated Motor Current
Inverter
Required Inverter Settings
Seconds
Once operating temperature is reached, this device quickly changes the resistance;
INSTALLATION
The motor must be wired to provide a clockwise direction of the cam.
Electric Motors for hazardous areas are specially designed to comply with official regulations concerning the risk
of explosion.
If improperly used, badly connected, or altered no matter how minor, their reliability could be in doubt.
it must be connected to a suitable releasing device mounted within the control panel and wired to stop the motor
if an over temperature occurs.
Rated Motor Voltage
80 Hz
Mininmum Hz Output 20 Hz
Acceleration Ramp
The motor is fitted with PTC temperature sensors (Thermistors).
Deceleration Ramp
Rated Motor Power 0.37 kW
5
Rated Motor Frequency 50 Hz
77-3245 R1.0 7/36 www.carlisleft.com