40 | 6. Tweaker Menu
ODT Delay Duraon Conguraon
ODT Read Duraon
This item allows you to controls the length of the ODT pulse for read commands. Default is 6
DCLK cycles (BL / 2 +2)
Opons: Auto (Default)
ODT Read Delay
This item allows you to controls delay from RD-CAS to ODT asseron in DCLK cycles.
Opons: Auto (Default)
OODT Write Duraon
This item allows you to controls the length of the ODT pulse for write commands. Default is 6
DCLK cycyles(BL / 2 +2)
Opons: Auto (Default)
ODT Write Duraon
This item allows you to controls delay from WR-CAS to ODT asseron in DCLK cycles
Opons: Auto (Default)