EasyManua.ls Logo

Bircher Reglomat Jupiter - Function Overview (Remote Control Unit); Motion Detector Functions; Presence Detector Functions; General Functions Overview

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
Technical dataFunction overview (remote control unit)
Section Function Key combination Levels
Motion detector
4.1 Output signal active/passive/OFF
+ + …
312F
*active passive
OFF
3
21
4.2 Comfort functions
+ …
51C
see page 24
4.3 Direction recognition
+ + …
218F
*ON
OFF
2
1
4.4 Field size (sensitivity)
+ …
91D
, , small
, , * medium
, , large
987
654
321
4.5 Additional output fall-delay time
+ + …
611F
0.2 s, short 0.5 s, short
*1.0 s, medium 2.0 s, medium
3.0 s, long 5.0 s, long
65
43
21
4.6 Cross-traffic optimisation
+ + …
915F
*OFF
,low
, , medium
, , high
987
654
32
1
4.7 Slow Motion Detection (SMD)
+ + …
913F
OFF, no SMD
* short, decreasing
long, decreasing
short, constant
long, constant
98
76
54
32
1
4.8 Field size SMD
+ + …
917F
, , small
,*, medium
, , large
987
654
321
4.9 Digital filter functions
+ + …
416F
interf. supp. filter ON
*OFF
door filter ON
interf. supp. filter + door filter ON
4
3
2
1
Presence detector
10.1 Output signal active/passive/OFF
+ + …
312E
*aktive passive
OFF
3
21
10.2 Test input (polarity)
+ + …
213E
* high active
low active
2
1
10.3 Test input delay
(dependent on test frequency)
specification ± 10%
Pulse-break ratio 1:1
at 10 Hz at 50 Hz at 100 Hz
+ +
*
14E
4 ms 3.7 ms 3 ms
+ +
24E
6 ms 5 ms 4 ms
+ +
34E
8 ms 6 ms 4.6 ms
+ +
44E
10 ms 7 ms
+ +
54E
12 ms 8 ms
+ +
64E
14 ms 9 ms
+ +
74E
16 ms
+ +
84E
18 ms
+ +
94E
20 ms
10.4 Manual teach-in of the background
+
3A
Teach-in of background
10.5 Teach-in time + + …
916E
*1min, medium 8 s, short
15 s, short 30 s, short
2 min, medium
5 min, medium
15 min, long 30 min, long
Infinite
9
87
65
43
21
10.6
Teach-in mode
+ + …
215E
fixed
* adaptive
2
1
10.7 Width of detection area
+ …
91B
see section 10.7
10.8 Sensitivity
+ + …
411E
high 1
* high 2
low 1
low 2
43
21
10.9
Deactivate presence detector
temporarily
+ +
+
2A
21A
+ deativate
*
activate (automatic mode)
2
21
10.10 Depth of detection area
+ + …
317E
see section 10.10
General functions
20.2
21.3
Configuration mode
+ +
+ +«Code»+
C9C
31A
deactivate configuration mode
activate configuration mode
14
Manual detection (15 min.)
+ +
+
2A
11A
+
activate manual detection
*
automatic mode
2
11
15 Combined outputs
+ + …
219E
**
ON
*OFF
2
1
16 (21) Access code
++ +
CXXXX9C
1111*–9998 save/switch on
9999 delete
17 Reset
+
9A
Factory default settings
18 Self-test
+ + …
414A
*All self-tests ON
Floor self-test OFF, module self-test ON
Floor self-test ON, module self-test OFF
All self-tests OFF
4
3
2
1
*Factory default settings **Factory default setting Jupiter Presence

Table of Contents