Bird SiteHawk Operation Manual
25
Note: If a maximum distance less than the total length of the
cable system is selected, the trace will not show the end of the
cable system (antenna). To display the full cable system always set
the maximum distance to a value that is a few feet or meters
greater than the entire length of the cable system.
A large spike (fault) near the SiteHawk Analyzer will mask other faults farther
away. When a large spike near the Site Analyzer is found, fix it and then repeat
the Fault Location measurement.