23KB-100-6 RUS
Internal pressure relief valve
for
4NCS-12.2(Y),4NCS-20.2(Y)
44NCS-24.2(Y), 44NCS-40.2(Y)
4VDC-20Y
4NES-12Y, 4NES-20Y
44NES-24Y, 44NES-40Y
The valve is maintenance free.
Repeated opening of the valve due to
abnormal operating conditions, how-
ever, may result in steady leakage.
Consequences are losses in capacity
and increased discharge temperature.
Check and replace the valve in this
case.
6.2 Oil changing
Oil changing is not normally neces-
sary for factory assembled plants. For
field installations and for applica-
tions near the operating limits a first
oil change is recommended after
approx. 100 operating hours. This
includes cleaning the oil filter and
magnetic plug.
After that the oil has to be replaced
approx. every 3 years or 10 000 ..
12 000 operating hours. Clean also oil
filter and magnetic plug.
Oil types: See chapter 2.
Attention!
Ester oils are strongly hygro-
scopic.
Moisture is chemically com-
pounded with these oils. It can-
not be, or only insufficiently,
removed by evacuation.
Handle very carefully:
Avoid air admission into the
plant and oil can. Use only
originally closed oil drums!
Dispose of waste oil properly!
Âñòðîåííûéïðåäîõðàíèòåëüíûéêëàïàí
äëÿ
4NCS-12.2(Y),4NCS-20.2(Y)
44NCS-24.2(Y),44NCS-40.2(Y)
4VDC-20Y
4NES-12Y,4NES-20Y
44NES-24Y,44NES-40Y
Äàííûéêëàïàíîáñëóæèâàíèþíå
ïîäëåæèò.
Îäíàê îìíîã îêðàòíîåïîâòîðíîå
îòêðûòèåäàííîãîêëàïàíàâñëåäñòâèå
íåíîðìàëüíûõóñëîâèéýêñïëó à òàöèè
ìîæåòïðèâåñòèêóòå÷êàìõëàäàãåíò à.
Ñëåäñòâèåìýòîãîá óäåòÿâëÿòüñÿïàäåíèå
ïðîèçâîäèòåëüíîñòèèðîñòòåìïåð à òóðû
íàãíåò àíèÿ.Âýòîìñëó÷àåñëåäóåò
ïðîâåðèòüè,ïðèïîòðåáíîñòè,çàìåíèòü
ïðåäîõðàíèòåëüíûéêëàïàí.
6.2 Çàìåíàìàñëà
Çàìåíàìàñëàâõîëî äèëüíûõóñòàíîâêàõ
çàâîäñêîéñáîðêèíåîáÿçàòåëüíà.Ïðè
ìîíò àæåóñòàíîâêèâ«ïîëåâûõó ñëîâèÿõ»
èëèïðèýê ñïëóàòàöèèêîìïðåññîðà
âáëèçèãðàíèöîáëàñòèïðèìåíåíèÿ
ðåê îìåíäóåòñÿâûïîëíèòüïåðâ óþçàìåíó
ìàñëàïðèáëèçèòåëüíî÷åðåç1 00ðàáî÷èõ
÷àñîâ.Ýòàïðîöå äóð àò àêæåïðåäóñìà òðè
-
âàåòçàìåíóìàñëÿíîã îôèëüòðàè
ìàãíèòíóþëîâóøêóìåòàë.÷àñòèö.
Ïîñëåýòîãîìàñëîçàìåíÿòü,ïðèìåðíî,
êàæäûå3ã îäàèëè,ñîîòâåòñòâåííî,
10 000..1 2 000ðàáî÷èõ÷àñîâ.Òàêæ å
ñëåäóåòïðî÷èùàòüìàñëÿíûéôèëüòð
èìàãíèòíóþëîâóøêó.
Ìàðêèìàñåë:ñì.ãëàâó2.
Âíèìàíèå!
Ïî ëèýôèðíûåìàñëàîáëàäàþò
çíà÷èòåëüíîéãèãðîñêîïè÷íîñòüþ.
Âëàã àõèìè÷åñêèñâÿçûâàåòñÿñ
ýòèìèìàñëàìè.Ïî ëíîñòüþå¸
óäàëèòüâàêóóìèðîâàíèåìíåâîç
-
ìîæíî,òîëüêîëèøüâíåáî ëüøîì
ê îëè÷åñòâå.
Íåîáõ îäèìî÷ðåçâû÷àéíî
îñòîðîæíîåîáð àùåíèå!Èñêëþ÷èòü
âîçìîæíîñòüïðîíèêíîâåíèÿ
âîçäóõàâó ñòàíîâêóèâòàðóñ
ìàñëîì!
Îòðàáîòàííîåìàñëîóòèëèçèðîâàòü
ññîá ëþäåíèåìïðàâèëçàùèòû
îêðóæàþùåéñðåäû!
Integriertes Druckentlastungsventil
für
4NCS-12.2(Y),4NCS-20.2(Y)
44NCS-24.2(Y), 44NCS-40.2(Y)
4VDC-20Y
4NES-12Y, 4NES-20Y
44NES-24Y, 44NES-40Y
Das Ventil ist wartungsfrei.
Allerdings kann es nach wiederholtem
Abblasen auf Grund abnormaler Be-
triebsbedingungen zu stetiger Lecka-
ge kommen. Folgen sind Minder-
leistung und erhöhte Druckgas-
temperatur. Ventil prüfen und ggf.
austauschen.
6.2 Ölwechsel
Ölwechsel ist bei fabrikmäßig gefertig-
ten Anlagen nicht zwingend erforder-
lich. Bei Feld-Installationen oder bei
Einsatz nahe der Einsatzgrenze emp-
fiehlt sich ein erstmaliger Wechsel
nach ca. 100 Betriebsstunden. Dabei
auch Ölfilter und Magnetstopfen reini-
gen.
Danach etwa alle 3 Jahre bzw. 10 000
.. 12 000 Betriebsstunden Öl wech-
seln. Dabei auch Ölfilter und Magnet-
stopfen reinigen.
Ölsorten: siehe Kapitel 2.
Achtung!
Esteröle sind stark hygrosko-
pisch.
Feuchtigkeit wird im Öl chemisch
gebunden. Es kann nicht oder
nur unzureichend durch Evaku-
ieren entfernt werden.
Äußerst sorgsamer Umgang
erforderlich:
Lufteintritt in Anlage unbedingt
vermeiden. Nur Original ver-
schlossene Ölgebinde verwen-
den!
Altöl umweltgerecht entsorgen!