ST-120-36
3.1 Technical data
Protection devices
SE-E1 SE-E2 SE-E3 SE-i1 SE-B2 OFC
Operating voltage
115 / 230V
+10/-15%
24..240V
+10/-25%
115 / 230V
+10/-15%
115..230
+10/-15%
230V
+10/-15%
230V
±10%
Operating fre-
quency
50/60HzAC 50/60Hz
AC/DC
50/60HzAC 50/60 HzAC 50/60HzAC 50/60HzAC
Motor voltage
200..600V
±10%
80..575V
±10%
600..690V
±10%
200..690V
±10%
--- ---
Motor frequency
range
50/60HzAC 20..100Hz
AC
50/60HzAC 20..135Hz
AC
--- ---
Relay:
Switching
voltage U
switch
240VAC 240VAC
min. 100mV
240VAC 250VAC 240VAC 250VAC
Continuous cur-
rent I
continuous
max. 2.5A max. 2.5A
min. 0.5mA
max. 2.5A max. 2.5A max. 2.5A max. 5A
Switching capa-
city I
switch
300VA 300VA 300VA 300VA 300VA 300VA
Allowable ambient
temperature
-30°C..
+60°C
-30°C..
+70°C
-30°C..
+60°C
-30°C..
+60°C
-30°C..
+70°C
-20°C..
+60°C
Required fuse
4A quick
acting
4A quick
acting
4A quick
acting
4A quick
acting
4A quick
acting
4A quick
acting
Enclosure class ter-
minals
IP00 IP00 IP00 IP20 IP00 IP00
Suitable for opera-
tion with frequency
inverter
--- 80..575V
±10%
20..100Hz
AC ②
--- 83..690V
+10%
50/60 Hz AC
--- ---
UL homologation
Yes --- --- is being pre-
pared
--- ---
Tab.3: Overview of the technical data of the protection devices for screw compressors (in the case of differing requirements/operating condi-
tions, consultation with BITZER is recommended)
①: The SE-E2 has a relay with gold contacts. After a
first operation at AC/DC>36V or >50mA,the min-
imum switching voltage is AC/DC>24V and the min-
imum continuous current is >20mA.
②: Suitable for operation with soft starter at a ramp
time shorter than 1s.
③: For operation with soft starter: 200..690VAC,
±10%, 50/60HzAC
EMC: All protection devices comply with the EU EMC
directives 2014/30/EU and 2004/108/EC.
Interference immunity:
EN61000-6-1:2007, Immunity for residential, commer-
cial and light-industrial environments.
EN61000-6-2:2005, Immunity for industrial environ-
ments.
Emitted interference:
EN61000-6-3:2007 +A1:2011, Emission standard for
residential, commercial and light-industrial environ-
ments.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bitzer OFC and is the answer not in the manual?

Bitzer OFC Specifications

General IconGeneral
BrandBitzer
ModelOFC
CategoryProtection Device
LanguageEnglish

Related product manuals