3-35 ScrOperationMode
Set the operation mode. This function is only available on SPP-R210 SCR.
long ScrOperationMode(uint mode, char *pResponse);
[Parameters]
* UINT mode
[in] Operating mode.
Constant
Value
Description
SCR_MODE_APDU
0
APDU mode
SCR_MODE_TPDU
1
TPDU mode
* char *pResponse
[in, out] Response to power up
[Return Values]
Constant
Value
Description
SUCCESS
0
The function is successful.
WRITE_ERROR
-105
Data transmission failed.
NOT_SUPPORT
-124
The function is not supported.
SCR_RESPONSE_ERROR
-126
The response data is incorrect.
* Example
int ret;
char response = 0xff;
ConnectToPrinter(………..);
……
ret = ScrOperationMode(SCR_MODE_APDU, &response);
if (0x00 != response)
return;
……