Chapter 3: Configuration
3. Configuration
There are no DIP switch or jumper settings that need to be modified in order to operate the basic functrions of the A/B Switch.
There are, however, several parameters related to Ethernet remote access/control and the automatic switching features that are
configurable. These settings are described later in this manual.
NOTE: The internal jumpers and DIP switches inside the A/B Switch have been pre-configured at the factory and should not be
changed from their default settings. They are shown here for reference only.
Table 3-1. Jumper settings.
Jumper Position Function
W1 1–2 position no Ethernet control module (SW1040A)
2–3 position Ethernet control module (SW1041A)
W2 1–2 position no Ethernet control module (SW1040A)
2–3 position Ethernet contol module (SW1041A)
NOTE: DIP switch SW1 (resistors may be installed for “closed” positions).
Table 3-2. DIP Switch SW1 settings.
SW1 Position Function
1 Open Latching relays (SW1040A, SW1041A)
1 Closed Not used
2 Open No Ethernet control module (SW1040A)
2 Closed Ethernet control module (SW1041A)
38 Open Reserved for future use