Operating Instructions BMP-E165
Section 2 – Technical Data April 2006
©Blastrac April 2006
13
2.4
Applications and Proper Use (cont’d)
A dust collector system MUST be used with this scarifier. The
minimum requirement of the dust collector is 200 CFM with primary
filter efficiency of 99.9% @ 0.5 Microns
2.5 Power Requirements for Electric Machine
If the machine is to be operated with a generator, the generator must
be connected in accordance with the National Electric Code (NEC).
Particular attention must be given to the equipment grounding
conductor in the system. See Section 1.2, Page 4 “Dangerous voltages
power this equipment. Etc” for explicit information. Only by doing this
are you ensured that all safety devices will function properly and
exclude the possibility of injury of personnel or of damage to electrical
components.