10
EN
DO NOT USE A METAL SCREWDRIVER, KNIFE, ETC. FOR ADJUSTMENT
OPERATIONS NOT TO DAMAGE THE CIRCUIT BOARD.
T
o
2 min
30 min
H
60%
90%
for H/SH
for T/H/ST/SH
FAN SETUP
— to adjust the humidity set point, turn the control knob H clockwise to increase and counter-clockwise to decrease the
humidity sensor set point, adjustable from 60 % up to 90 %.
— to adjust the fan turn-off delay time, turn the control knob T
o
clockwise to increase and counter-clockwise to
decrease the turn-off delay time respectively, adjustable from 2 up to 30 minutes.
The fan delivery set includes a specially designed
plastic screwdriver for fan settings adjustments. Use it
to change the turn-on and turn-off delay time and the
humidity set point.
THE TIMER CIRCUIT IS LIVE.
MAKE SURE THE FAN IS DISCONNECTED FROM POWER SUPPLY.