TO ENSURE OPTIMAL PERFORMANCE FROM YOUR ICEMAKER, THE
FOLLOWING IS RECOMMENDED –
Ensure that the minimum water temperature is not lower than
+5°C or higher than +40°C
Minimum water pressure is not below 0.1MPa and maximum does
not exceed 0.5MPa
The electrical supply available corresponds to the voltage and
ampacity of the machine specifications as indicated on the rating
plate
The electrical cut off switch with fuse protection must be a 2 pole
type with minimum clearance of 3mm between open contacts
The minimum ambient temperature should not be lower than
+10°C or the maximum higher than +40°C
Ensure there is a minimum space around the cabinet vents of
150mm to allow air circulation.
Ensure there are no heat sources (kitchen stoves, cookers, radiators
etc) near the machine and the environment isn’t too humid.
INSTALLATION
Check the machine is level, and connect the plug to the electrical
cord in compliance with local regulations
Replace any old/used water hoses with new ones and connect to the
water supply
Ensure the drain is connected and set up properly using a spiralled
hose. It should have a minimum fall of 3cm per metre
Open water shut off valve
Insert plug into mains socket and set the main switch to the ON
position.