BL6-U Parallel Integrated Controller Quick Commissioning User Manual
37
Running Setup Parameters List (Cont'd)
P2: Acceleration speed decrease
rate at end of elevator start; smaller
value means end of elevator start
with slow and steady movement.
P3: Deceleration speed increase
rate at beginning of elevator brake;
smaller value means beginning of
elevator brake with slow and steady
movement.
P4: Deceleration speed decrease
rate at end of elevator brake;
smaller value means end of elevator
brake with slow and steady
movement.
Motor speed less than set value,
system considers elevator speed as
zero and generates brake signal.
Adjust differences of up/ down
leveling
Normally used in synchronous
machine system, compensate
elevator load based on steel rope
weight difference on each floor.
Selection of driving mode, when
setting “1”, attendant/VIP mode
close door manually; when setting
“3”, elevator automatically do test
run, other value is invalid.
Setup rear door mode, based on
customer requirements, set from
mode”0” to”5”.
Three Fire modes:
1.Mode”0”: Elevator run fire-mode
after returning to fire floor;
2.Mode “1”: Elevator stop running
after returning to fire floor;
3. Mode “2”: After elevator return
to fire floor, depend on fire switch
to run/stop in fire mode.
Set “YES” in duplex enable. Set
elevator number 0-1 in duplex; 0-7
in group control.
Elevator duplex control:
1: ON 0: OFF
Elevator group control:
1: ON 0: OFF
Remote Monitoring System:
1: ON 0: OFF
Auto parking:
1: ON 0: OFF
Load Weighing:
1: ON 0: OFF
Door open/close delay:
1: ON 0: OFF
Test brake feedback signal:
1: open 2: close
Password to release elevator stop.