BL6-U Parallel Integrated Controller Quick Commissioning User Manual
38
Time Setup Parameters List
Para
No.
Display
Content
Range
Factory
Setting
Unit
Live
Change
F2-00
Brake ON Time
Brake open first then run elevator speed
curve. This is to improve the elevator start
comfort and match control system with
different machine brake on time.
0.00
~
9.99
0.5
s
Y
F2-01
Brake OFF Time
Brake close first then disable elevator run.
This is to improve elevator stop comfort
and avoid slip at elevator stop.
0.00~
9.99
0.5
s
Y
F2-02
Insp Brake Time
The time delay in inspection mode before
brake close.
0.00~
9.99
0.05
s
Y
F2-04
Zero Time
The time delay when system detects
elevator stop. Adjust this parameter to
close brake after elevator reach 0 speed
completely, increase elevator stop comfort.
0~9.99
0.21
s
Y
F2-05
Open Door Time
In Auto mode, elevator automatically open
door when stopping at one floor, door will
automatically close after set time.
0~999
5
s
Y
F2-06
Open Delay Time
Enable door open delay function, press
open delay button, door open time will be
delayed.
0~999
60
s
Y
F2-07
Homing Time
The waiting time before elevator return to
homing floor without landing/car call, set
value to “0” to disable this function.
0~999
60
s
Y
F2-08
Door Run Time
1. The door open/close command run time;
2. Door open/close relay run time for door
drive without open/close limit switch.
3. For door drive with open/close limit
switch, this run time should be 1s longer
than the door actual open/close time.
0~999
5
s
Y
F2-09
Beep Delay Time
After elevator change speed to target floor,
landing signal is delayed by set time, arrival
gong /voice synthesizers are also delayed
by set time.
0.00~
9.99
0.15
s
Y
F2-10
Enable Delay
Drive enable signal given/drop is delayed
by set time after drive direction signal is
given/drop. During this time, drive output
current is decreased to reduce current
noise.
0.00~
9.99
0
s
Y
F2-11
Lamp Off Time
In Auto mode, if have no car/landing call
during set time, system will cut car light
power from COP.
0~999
15
min
Y
F2-12
Over Time
To prevent wire rope slipping or elevator
car stuck, time from elevator running to
stop is limited to set value. If elevator is
running longer than set value, system stops
immediately and enter protection mode.
Need to re-start the system in order to exit
from such mode.
0~999
45
s
Y
F2-13
SmoothStart Time
The time to keep elevator start smooth.
0.00~9.
99
0.5
s
Y
F2-14
F2-15
Start Time
System will automatically start the elevator
(Electric lock: ON) at set time.
00:00
23:59
00:00
Hou
r:
min
ute
Y
F2-16
F2-17
Stop Time
System will automatically stop the elevator
(Electric lock: OFF) at set time. This
function is disabled if same start/stop time.
00:00
23:59
00:00
Hou
r:
min
ute
Y