BL6-U Parallel Integrated Controller Quick Commissioning User Manual
42
Special Funct
Motor Setup Parameters List
Para
No.
Display
Content
Range
Factory
Setting
Unit
Live
Chang
F5-00
Motor Type
Set motor type (0: sync- outer
rotor, 1: async machine, 2:
sync-inner rotor)
0~2
0
--
N
F5-01
Poles
Moto poles (Nameplate)
1~99
20
--
N
F5-02
Sync Freq
Motor synchronous frequency
(Nameplate)
0.001
~99.999
16
Hz
N
F5-03
Rated Power
Motor rated power
(Nameplate)
1~50
6.7
kW
N
F5-04
Rated Speed
Motor rated speed (Nameplate)
1~1999
96
RPM
N
F5-05
V IN
Motor counter-EMF
(Nameplate)
1~380
280
V
N
F5-06
L_phase
Motor phase inductance set.
(Auto-tuning/ manual input)
Auto-tuning/
Nameplate
mH
N
F5-07
R_phase
Motor phase resistance set.
(Auto-tuning/ manual input)
Auto-tuning/
Nameplate
Ω
N
F5-08
Rated FLA
Motor rated current.
(Nameplate)
0~
99.999
A
N
F5-09
NO-Load Current
For asynchronous machine,
no-load excitation current.
0.1~50
0
A
N
F5-10
Rated Slip
For asynchronous machine
rated slip. (Nameplate)
0.1~10
1.3
HZ
N
F6-00
Carrier Freq
Set controller carrier frequency.
6~15
8
kHz
N
F6-02
SpeedZoom
Speed Zoom (Reduce elevator
actual running speed)
0~100
100
%
Y
F6-03
DirSel
Select motor running direction
(0/1: Motor rotates anti-
clockwise, car move down/up).
0/1
0
--
--
F6-04
Kp
Speed loop proportional gain.
(Valid for complete curve if not
used in multiple PI.)
0~65535
1000
--
--
F6-05
KI
Speed loop integral gain. (Valid
for the complete curve if not
used in multiple PI.)
0~65535
600
--
--
Number
Instruction
F4-07-27
ON: Enable brake force self-test function. Automatically start at 3: 00AM or manually start by modify
F4-07-30. Default: ON
OFF: Disenable brake force self-test function. (control software 1000_5600 and the above version
support this function)
F4-07-28
Reserved.
F4-07-29
ON: Leveling adjustment can be set separately. The default Leveling adjustment of each floor (1~64
floor) in setting parameters is 50mm.
F4-07-30
1. Every time turn to ON from OFF, act brake force self-test once. Keep ON will be ineffective;
(1000_56xx)
2. open the door open waiting function for any floor. (1000_55xx)
F4-07-31
Reserved.