BL6-U Parallel Integrated Controller Quick Commissioning User Manual
42
Special Funct
Motor Setup Parameters List
Set motor type (0: sync- outer
rotor, 1: async machine, 2:
sync-inner rotor)
Motor synchronous frequency
(Nameplate)
Motor rated power
(Nameplate)
Motor rated speed (Nameplate)
Motor counter-EMF
(Nameplate)
Motor phase inductance set.
(Auto-tuning/ manual input)
Motor phase resistance set.
(Auto-tuning/ manual input)
Motor rated current.
(Nameplate)
For asynchronous machine,
no-load excitation current.
For asynchronous machine
rated slip. (Nameplate)
Set controller carrier frequency.
Speed Zoom (Reduce elevator
actual running speed)
Select motor running direction
(0/1: Motor rotates anti-
clockwise, car move down/up).
Speed loop proportional gain.
(Valid for complete curve if not
used in multiple PI.)
Speed loop integral gain. (Valid
for the complete curve if not
used in multiple PI.)
ON: Enable brake force self-test function. Automatically start at 3: 00AM or manually start by modify
F4-07-30. (Default: ON)
OFF: Disenable brake force self-test function. (control software 1000_5600 and the above version
support this function)
ON: Leveling adjustment can be set separately. The default Leveling adjustment of each floor (1~64
floor) in setting parameters is 50mm.
1. Every time turn to ON from OFF, act brake force self-test once. Keep ON will be ineffective;
(1000_56xx)
2. open the door open waiting function for any floor. (1000_55xx)