15
D
1
2
3
4
5
6
7
EN
Activating collision avoidance
To avoid the collision of fronts, drive units (max� 6) are linked so that
only one front can be opened at a time� A front is prevented from
opening as long as a linked front remains open�
Activating the SERVO-DRIVE switch → see A 1–3
Press the <COLL> button for the first drive unit
until the LED display flashes green�
Close the front manually
Open the second front manually
Press the <COLL> button for the second drive unit
until the LED displays for both drive units light up continuously green�
Repeat procedure D 25 for all additional cabinets�
Carry out reference run → see B 1–4
E-training Lights up continuously Flashes
If there is an activation error, reset the functions of all drive units →
see Reset Wireless F 1
NOTE
Re-activate the SERVO-DRIVE switch, collision avoidance and refe-
rence run → see A 13, D 26 and B 14