EasyManua.ls Logo

BLUM SERVO-DRIVE

BLUM SERVO-DRIVE
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
EN
EN
SERVO-D RIVE
Instruction leaet
Supply voltage: ..................................................................................................................... 24.0 V DC
Rated current: ................................................................................................................................ 2.0 A
Power consumption in standby mode: ............................................................... ≤ 0.15 W (front closed)
Operating mode: .............................................................................. S3 5 % (max. 10 motions/10 min.)
Emission sound pressure level: ............................................................................................ < 70 dB(A)
Ambient conditions:
Transport / Storage: ......................................................................... -30 to +70 °C / 0 to 90 % r.H.
Operation: ................................................................. 0 to +40 °C / 5 to 80 % r.H. non condensing
Maximum altitude: ................................................... 2000 m (at an ambient temperature of 25 °C)
Protection category: ........................................................................................................................ IP20
Supply voltage: ..................................................................................................................... 24.0 V DC
Rated current: ................................................................................................................................ 2.0 A
Power consumption in standby mode: ............................................................... ≤ 0.15 W (front closed)
Power consumption in standby mode (with wireless receiver): ......................... ≤ 0.35 W (front closed)
Operating mode: .............................................................................. S3 5 % (max. 10 motions/10 min.)
Emission sound pressure level: ............................................................................................ < 70 dB(A)
Ambient conditions:
Transport / Storage: ......................................................................... -30 to +70 °C / 0 to 90 % r.H.
Operation: ................................................................. 0 to +40 °C / 5 to 80 % r.H. non condensing
Maximum altitude: ................................................... 2000 m (at an ambient temperature of 25 °C)
Protection category: ........................................................................................................................ IP20
Radio equipment (with wireless receiver):
Frequency band: .............................................................................................. 2.404 to 2.452 GHz
Maximum radio-frequency power: ....................................................................... +4 dBm / 2.5 mW
Range: ........................................................... typically 10 m (depending on material and contents)
Transmission method: ...................................................................... bidirectional, via a coded wire
SERVO-DRIVE ex drive unit Z10C5000
SERVO-DRIVE drive unit for LEGRABOX / MERIVOBOX /TANDEMBOX / MOVENTO / TANDEM
Z10A3000.03, Z10A3000.50