System overview
by Blum-Novotest 2012 11
TC62
TC63-10 /
TC76-T
TC64-10
Approach direction
± X, ±Y, -Z
± X, ±Y, ±Z
a)
± X, ±Y, ±Z
a)
Measuring force XY-
direction
see Tab. 2.6 - Tab. 2.8
Measuring force Z-
direction
5,7 N
1,6 N (LF)
10 N (TC62 T)
5,9 N
2,0 N (LF)
5,9 N
2,0 N (LF)
10,6 N (TC64-10 T)
Max. deflection XY
see Tab. 2.5
± 11°
± 9° (TC62 T)
± 15° ± 15°
Max. deflection Z 6 mm
3,5 mm (TC62 T)
5 mm 5 mm
Max. acceleration 50 m/s
2
200 m/s
2
(TC62 T)
50 m/s
2 b)
50 m/s
2
200 m/s
2
(TC64-10 T)
Repeatability* 0,3 µm 2σ (Standard)
Z: 0,2 µm 2σ (LF)
XY: 0,3 µm 2σ (LF)
0,4 µm 2σ 0,4 µm 2σ
Max. probing speed 2 m/min 2 m/min 2 m/min
Mass 250 g
225 g
(TC63-10)
230 g
Protection class
IP 68
Signal transmission
Radio
Frequency band 2,4000 – 2,4835 GHz
Transmission power 0 dBm
Operating range
5 m
Battery life
Saft Lithium LS 14250 (½ AA 3,6V)
Tool holder HSKSK-BT
BTH 25
Operating temperature
+5 °C ... +50 °C
Storage temperature
-20 °C ... +70 °C
* stylus L=30 mm
a)
see chap. 3.5
b)
with accessories (e.g. extension, angle): max. acceleration 10 m/s
2
Tab. 2.4