NPA70DA USER MANUAL
www.blustream.com.au | www.blustream-us.com | www.blustream.co.uk16
RS-232 / TELNET COMMAND DESCRIPTION
OUT DLYT yy Set Output Delay Time to yy(ms)
yy=[1..50]:Delay Time, Millisecond
OUT REVB ON/OFF Set Output Reverb On Or O
OUT PHASE yy INV ON/OFF Set Output L-Inverter Or R-Inverter On Or O
yy=[0,1]0:LEFT,1:RIGHT
OUT MIX yy Set Output Mix yy
yy=[1,2]:1:STEREO,2:LEFT-CH
yy=[3,4]:3:RIGHT-CH,4:LEFT-CH and RIGHT-CH
OUT EQ yy VAL zz Set Output GEQ:yy to zz
yy=[1..31]:EQ Index
zz=[-10..3]:EQ Value
OUT EQ PRESET yy Set Output GEQ:yy to Preset:yy
yy=[1...3]:1:Flat,2:Custom1,3:Custom2
NET DHCP ON/OFF Set Auto IP(DHCP) On Or O
NET IP xxx.xxx.xxx.xxx Set IP Address
NET GW xxx.xxx.xxx.xxx Set Gateway Address
NET SM xxx.xxx.xxx.xxx Set Subnet Mask Address
NET TCPPORT xxxx Set TCP/IP Port
NET TN xxxx Set Telnet Port
NET RB Network Reboot and Apply New Config!!!
NET DNS xxxx Set DNS Domain Name To xxxx