RS-232 Page - Local
The RS-232 Page allows for commands to be sent from either the local RS-232 port on the Matrix itself, or via
HDBaseT™ and out of the compatible HDBaseT™ Receiver connected to the display. If the Local radio box is selected,
RS-232 commands will be sent out of the DB9 serial port at the rear of the Matrix to a connected device. Baud rate and
terminator command as well as HEX or ASCII can be selected.
Sending an RS-232 command out via the Matrix can be useful in assisting with debugging and fault finding an RS-232
device connected to the Matrix.
RS-232 Page - HDBT
The RS-232 HDBT Page allows for remotely control devices connected via DB9 serial to the remote HDBaseT™ Receiver
to be conrtrolled. It is then possible to automate the display on, input select, and display o process via RS-232 for
each HDBaseT™ output, when the Matrix is turned on or o.
If RS-232 On is enabled, the User Commands 1, 2, 3, 4, and 5 are all sent out of the HDBaseT™ Receiver, when the Matrix is turned
on. If RS-232 O is enabled, the User O Command will be sent out of the corresponding HDBaseT™ Receiver, when the Matrix is
turned o.
You can also specify the Baud Rate and Command Ending (eg: new line, carriage return) to the match the RS-232