EasyManua.ls Logo

Boge S 101 - Commissioning Following Extended Stoppages

Boge S 101
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Aufstellung.pm6.5 - USA
Page 3.11
Installation
BOGE Operating instructions for S 40-2...S 341 / SF 40-2...SF 220 series screw compressors
Commissioning
following extended
stoppages
If an extended stoppage is scheduled, you should contact BOGE-Service
beforehand.
Following an extended stoppage of more than 2 months, fill a small amount
of oil in the suction controller prior to starting the compressor.
CAUTION!
Only fill the suction controller with the grade of oil used to operate the com-
pressor.
Never mix different oil grades and brands.
DANGER: Risk of injury!
Switch off main switch and secure against unintentional switching-on.
Unscrew the plug on the suction controller .
The following quantities of compressor oil have to be filled into the intake
regulator:
approx. 0.13 gallon for models S 31-2 S 60-2
approx. 0.65 gallon for models S 61-2 S 100-2
approx. 1.30 gallon for models S 101 S 150
approx. 2.10 gallon for models S 151 S 220 / SF 220
approx. 2.65 gallon for models S 271 S 341
approx. 0.13 gallon for models SF 40-2 SF 60-2
approx. 0.65 gallon for models SF 100-2
approx. 1.30 gallon for models SF 150
Reclose the controller using the plug.
Turn the air end by hand 5 to 10 times to distribute the oil evenly.
Fig. 3.3: Suction controller
3.5 Commissioning
1

Table of Contents

Related product manuals