BOGE Operating instructions for S 40-2...S 341 / SF 40-2...SF 220 series screw compressors
Fig. 5.7: Checking the oil level, topping up with oil Note:
Switch off the compressor using the OFF button.
DANGER: Risk of injury!
Switch off the main switch and secure it against unintentional switch-on.
Close ball valve at the compressed air outlet.
Vent the compressor (as described in the beginning of the chapter).
The system pressure gauge must indicate a pressure of 0 psig.
Wait approx. 3 minutes to permit the oil to settle.
Remove cladding on the maintenance side.
DANGER: Risk of injury!
Danger of burning due to hot oil!
Remove plug of oil filling socket .
Check oil level.
The oil level must not drop below the "min" mark (see sketch).
If necessary, top up with oil to the lower edge of the thread ("max." mark)
on the oil filling socket.
Screw plug with viton seal back in.
Reattach clading on the maintenance side.
Open ball valve at the compressed air outlet.