Orion ISS
www.bolid.com 44
Condition/Event Category Sound Signaling
Forced open (the door is open without
access granted)
Held open (the door is open for more
than a specified time, 20 s by default)
Door Held
or Forced
Open
Interrupted sounds 4 times per second
Loop Alarm
Loop
Alarms
Interrupted sounds 2 times per second
Entering the User key programming
mode
Program-
ming
Three pairs of short sounds
(‘Programming’)
Exiting the User keys programming
mode
Program-
ming
3 short + long sounds
(‘Programming is finished’)
Entering the Master key programming
mode
Program-
ming
‘Master Programming’ melody
A Master key is programmed
Program-
ming
The final part of the ‘Master Program-
ming’ melody
A key is added or modified while the con-
troller being in key programming mode
Program-
ming
Two short sounds (‘Code saved confir-
mation’)
Presenting an existing key while the con-
troller being in key programming mode
Program-
ming
A short sound
(‘The key has already been enrolled’)
NOTE: Sound alarms can be disabled for any signal category (Access, Door Held or Forced Open,
Programming, or Loop Alarms) both for the C2000-2 built-in sounder and each sounder of
the readers individually. It can be done while programming the relevant parameters of
S2000-2 by means of the UProg Configuration Tool see S2000-2 Programming Section of
this Manual.