The S2000-2 configuration parameters are to be modified by UPROG Configuration Tool software
of 4.0.0.821 version or later which operates on a PC under the Windows-98 and higher. Program-
ming all the parameters of the controller (including the key serial number length, access templates
and possibility to program up to 8192 keys in the S2000-2 rev.01) are provided via the UPROG Con-
figuration Tool software of 4.0.0.915 version or later. The configuration of the S2000-2 is stored in
the S2000-2 non-volatile memory.
The controller can be connected to the COM-port of the computer through the following: the PI-GR
Interface Converter, the S2000-PI Interface Converter/Extender, the S2000-USB Interface Converter,
and the S2000 Console (version 1.20 and higher) or the S2000M Console.
The most up-to-date version of UPROG.EXE can be found on the web site of the Bolid Company at
the address www.bolid.com
, in DOWNLOAD section.
The S2000-2 controller has eight groups of configuration parameters:
¾ System configuration parameters
¾ Parameters of readers
¾ Parameters of alarm loops
¾ Parameters of relays
¾ Parameters of access groups
¾ Parameters of time schedules
¾ Parameters of keys
¾ Parameters of key patterns
SYSTEM CONFIGURATION PARAMETERS
System parameters of the controller’s configuration are given in the Table 6.
Table 6 System Configuration Parameters
Parameter Description Range
Default
value
Network Address
The unique number of
S2000-2 within the ad-
dress space of a network
controller
1…127 127
Operation Mode
The fundamental parame-
ter which define the con-
troller operation strategy
and its destination
1 (Two Entrance Doors)
2 (One Entrance/Exit Door)
3 (Turnstile)
4 (Swing-beam Barrier)
5 (Two Sluice Doors)
1