7 - Warning list
1
2
3
Read Operator Manual High current of the M1 motor Reduce the force
Read Operator Manual High current of the M2 motor Contact the Assistance Service
Wrong battery The battery is not correct
Replace the battery and use only
the batteries provided
4 Not ready, press RESET M1 motor in the wrong position Press RESET
5 Low Battery Voltage Discharged battery Replace the battery
6 Read Operator Manual Excessive pull time
Check the oil level or replace the
battery
7 Read Operator Manual
Excessive M2 screwing/unscrewing
time
Contact the Assistance Service
8 Bad M1 Position, press RESET High pull end position Check the oil level and press Reset
9 Pressure, please Check Oil Low oil pressure Check the oil level
10 Force not correct - -
11 M1 Motor, High Temperature Excessive M1 motor temperature
Wait a few minutes before
resuming work
12 M2 Motor, High Temperature Excessive M2 motor temperature
Wait a few minutes before
resuming work
13 Drive, High Temperature
Excessive temperature of the
electronics
Wait a few minutes before
resuming work
14 No Rivet Nut
®
on the mandrel
When enabled in menu “Start
condition” this alarm warns that
a rivet is not loaded
Load a Rivet Nut
®
on the mandrel
15 Error communication
Internal hardware communication
error between LCD CPU and M1
Drive board or M2 Drive board
Contact the Assistance Service
Error communication
Internal hardware communication
error between LCD CPU and M1
Drive board or M2 Drive board
Contact the Assistance Service16
17 Wrong battery The battery connected is not correct Replace the battery by a correct one
18 Nose not installed
When enabled means that the nose
is uninstalled
Check that the nose is correctly
installed against the body
19 M1 home reset Error doing M1 home reset
Push on “Reset button for driving
the system in rest position
21
22
Maintenance service needed
The number of cycles for inspection
is reached
Contact the Assistance Service or
realise the maintenance operations
At powerup at least one LCD
pushbutton is pressed
Check that the different button are
free / body
No. Text on the display Meaning Solution