EasyManua.ls Logo

Bomag BW 900-2 - Page 65

Bomag BW 900-2
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
As re quired
BOMAG
65
BW 900-2
As require d
5.25 Water sprinkler system,
maintenance in the event of
frost
!
Caution
In the event of frost the water sprinkler system
mustbedrainedorfilledwithananti-freeze
mixture respectively.
l Drain all water off.
l Switch the water sprinkler system on and let all
remaining water run out.
l Fill the water tank with approx. 5 l of anti-
freeze mixture (water and anti-freeze agent,
e.g. glycol).
l Run the sprinkler system, until the anti-freeze
mixture starts to run out from the sprinkler
tubes.
5.26 Tightening torques for
screws with metric unified
thread
Fig. 101
* Strength classes for screws with untreated, non-
lubricated surface. The quality designation of the
screws is stamped on the screw heads.
8.8 = 8G
10.9 = 10K
12.9 = 12K
The values result in a 90%ige utilization of the
screws yield point, at a coefficient of friction of tot.
= 0,14.
The compliance with the specified tightening tor-
ques is checked with torque wrenches.
The specified tightening torques do not apply
when using a MoS
2
lubricant.
i
Note
Self locking nuts must always be replaced after
they have been unscrewed.