EasyManua.ls Logo

Bomag BW 900-2 - Changing the Hydraulic Oil Filter Element

Bomag BW 900-2
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Every 2000 operating hours
BOMAG
64
BW 900-2
5.24 Changing the hydraulic oil
filter element
!
Danger
Danger of scalding!
Danger of scalding by hot hydraulic oil.
!
Caution
Do not reuse the oil in the filter.
Environment
Environmental damage
Catch running out oil and dispose of environ-
mentally.
i
Note
If the hydraulic oil filter contamination indicator on
the filter shows "red" when the engine is running
and at operating temperature, change the filter el-
ement.
With a clean oil filter the hydraulic oil filter contam-
ination indicator will show "green".
The filter element must be changed with every hy-
draulic oil change and after major repairs in the hy-
draulic system.
If the filter has to be changed together with the hy-
draulic oil, the filter must only be changed after the
oil change and after the test run.
Fig. 100
l Unscrew the filter bowl (Fig. 100) from the filter
housing.
l Take the old filter insert out and dispose of en-
vironmentally.
l Clean the filter bowl.
l Insert the filter element with the opening up-
wards and screw the filter bowl on, observe
the condition of the seal ring.