Instruction Manual for F1300/1600 Mud Pump
43
reasons should be found according to the trouble spot. After troubleshooting, the pump
can run normally.
6. Matters need attention for storage
1) When the pumps are not used for a long time, they should be stored.
2) Before storing, clean it carefully, empty each part of fluid end and clean it with water.
3)
Discharge the lubricant oil in the bottom of gear box of power end completely and remove the
deposits.
4)
Coat viscous lubricants on the finished surface of all bearings, crossheads, gears, piston rods,
extension rods etc.
5)
Coat grease on the machined surface of each parts of fluid end.
6)
Cover the suction inlet and discharging outlet with blind flange.
7)
The nose end cover, rear cover and the inspection hole cover of crosshead should be covered.
7. Explains for Order
7.1 Provided range of mud pump
One mud pump consists of pump main body; spray pump; pulsation dampener; safety value; tools;
spare parts for one time change of rubber seals.
Belt pulley and big skid are not included.
If there is not special required by users, spray pump is droved by belt and lubrication pump of power
end is inner droved style.
Normally,
φ170 liners and pistons are assembled in the pump when it is transported to users.
7.2 Metric system and British system
1) F-series mud pumps are divided into two basic styles: metric and British. Users choose it due to
their own demands and declare when ordering.
2) Metric pump adopts metric threads and British pump adopts American threads.
7.3 Drive rotation direction
If drilling rigs require the mud pumps reverse rotation, please order F-1300R/1600R reverse pump.
Follow characters belong to F-1300R/1600R the reverse pump:
1. The clearance between guides is 0.25-0.40mm (0.010~0.016in).
2. Upper guide and lower guide can exchange.
3. Connecting the oil pump oppositely.