OWNER’S MANUAL
READ BEFORE USE! Model No.: HYFP50095-3 Item No.: 68163
WARNING:
Do not store or use gasoline or
other flammable vapors and liquids
in the vicinity of this or any other
appliance.
An LP cylinder not connected for
use should not be stored in the
vicinity of this or any other appliance.
• Service must be performed by a
qualified installer, service agency or
the gas supplier.
DANGER
IF YOU SMELL GAS:
1. Shut off gas to the appliance
2. Extinguish any open flame
3. If odor continues, keep away from
the appliance and immediately call
your gas supplier or fire department.
WARNING: For Outdoor Use Only!
Use Liquid Propane Gas (LP-Gas) Only !
Propane cylinders sold separately.
WARNING:
Improper installation, adjustment,
alteration, service or maintenance can
cause injury or property damage. Read the
owners manual thoroughly before
installing or servicing this equipment. If the
information in this manual is not followed
exactly, a fire or explosion may result
causing property damage, personal injury
or loss of life. Save these instructions for
future use. If you are assembling this unit
for someone else, give this manual to him
or her to read and save for the future.
WARNING:
Turn off gas supply when the appliance
is not in use.
If the appliance is stored indoors,
detach and leave LP-Gas cylinder outdoors.
WARNING:
This appliance must be attended at all
times!
WARNING:
Battery may contain mercury. Do not
deposit in fire or put in trash. Recycle the
battery as hazardous waste.
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which
has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such
as a camper, tent, car or home.
Design certified under ANSI Z21.97 •
CSA 2.41-(2014) Requirements for
Outdoor Gas Fireplaces
USC

Questions and Answers

  • O
    omilesAug 1, 2025
    What to do if my BOND MANUFACTURING Outdoor Fireplace appliance won't light?
    • A
      Andrew MartinezAug 1, 2025
      If your BOND MANUFACTURING Outdoor Fireplace appliance won't light, there are several possible causes: * The igniter pin and burner may be wet. If so, wipe them dry with a cloth. * The igniter battery may be incorrectly inserted. Check that the battery is correctly inserted. * The electrode wire might be loose or disconnected. Reconnect the wire to the igniter box located inside the table base behind the igniter button. * For a cracked or broken igniter pin or if the electrode wire is shorting between the valve and igniter pin, you will need to call customer service for a replacement part.
  • S
    Stephen ReeseAug 7, 2025
    Why does my BOND MANUFACTURING HYFP50095-3 appliance emit a lot of black smoke when lit?
    • J
      Jennifer DayAug 7, 2025
      If your BOND MANUFACTURING Outdoor Fireplace appliance emits a lot of black smoke when lit, it could be due to: * The flame being obstructed at the burner ports. Ensure all gas burner ports are free of lava rocks or debris to allow the gas to flow freely. * A pinched regulator hose. Check the regulator hose for bends or kinks.
  • J
    Jamie GarnerAug 13, 2025
    What causes a sudden drop in gas flow in my BOND MANUFACTURING Outdoor Fireplace?
    • S
      susanbrownAug 13, 2025
      A sudden drop in gas flow in your BOND MANUFACTURING Outdoor Fireplace can be caused by: * An empty gas cylinder. Check if the gas cylinder is empty and replace it if necessary. * Activation of the excess flow safety valve. To reset, turn the control knob to "OFF", close the LP tank valve, and disconnect the regulator from the tank. Then, turn the control knob to "HIGH", wait 1 minute, and turn it back to "OFF". Reconnect the regulator to the LP tank, open the tank valve slowly, and light the appliance as indicated in the "To Light" section.
  • S
    Stephanie YorkAug 19, 2025
    What causes flame blow out in BOND MANUFACTURING HYFP50095-3?
    • A
      amy21Aug 20, 2025
      Flame blow out in your BOND MANUFACTURING Outdoor Fireplace can be caused by: * High or gusting winds. Increase the flame to "High" to compensate. * No gas flow. Check if the gas cylinder is empty and replace it if necessary. * The excess flow safety valve may have been activated. Refer to the "Sudden drop in gas flow" section for instructions.
  • A
    Andrew DixonAug 26, 2025
    What to do if burner will not light using a match in BOND MANUFACTURING HYFP50095-3?
    • J
      Jennifer WuAug 26, 2025
      If the burner will not light using a match in your BOND MANUFACTURING Outdoor Fireplace, consider the following: * Check if the gas cylinder is empty and replace it if necessary. * Ensure the regulator is fully connected to the tank. Check the LP tank connection. * Inspect the hose for any bends or kinks that may be obstructing gas flow. * Look for spider webs or insect nests in the venturi (end of the burner tube) and clean the venturi if necessary. * If the burner ports are clogged, insert an opened paperclip into each of the burner ports to clean them. Ensure the appliance is off and all parts are cooled before attempting to clean the burner ports.

Summary

Safety Warnings and Hazards

Outdoor Use Only

Specifies the appliance is designed for outdoor use exclusively.

Gas Leak Response Procedure

Immediate steps to take if gas odor is detected.

Carbon Monoxide Hazard Warning

Warns about carbon monoxide production and safe usage.

Operational Safety Precautions

Ignition Safety and Prohibited Uses

Avoid face proximity during ignition; prohibits cooking or burning other materials.

Liquid Propane (LP) Gas System Safety

LP Gas Characteristics and Hazards

Details LP gas flammability, explosiveness, and skin contact risks.

Cylinder Handling and Storage Procedures

Instructions for transporting, storing, and handling LP gas cylinders safely.

Leak Detection and Response Protocol

Steps for detecting and responding to gas leaks, including immediate actions.

LP Gas Tank and Appliance Management

Pre-Operation Checks and Lighting

Troubleshooting Appliance Issues

Ignition and Burner Problems

Diagnosing and fixing issues when the appliance won't light or the burner has problems.

Gas Flow and Flame Blowout

Addressing problems related to sudden drops in gas flow or flame blowouts.

Troubleshooting and Support

BOND MANUFACTURING HYFP50095-3 Specifications

General IconGeneral
BrandBOND MANUFACTURING
ModelHYFP50095-3
CategoryOutdoor Fireplace
LanguageEnglish

Related product manuals