Operation instructions
GAS CONTROL
SLIDE
ADJUSTMENT KNOB
_5
Fig. 10 Temperature Adjustment Controls
Temperature adjustment knob
The temperature adjustment knob on the front bottom of
the heater (see Fig. 10) adjusts temperature by
adjusting flow capacity. See table 4 for details.
Degree rise 90°F 45°F
Activation rate 0.5 GPM 1.1 GPM
Max flow rate 2.0 GPM 3.7 GPM
Table 4 Clearances
As the temperature adjustment knob is turned counter-
clockwise, the output temperature will lower and the
activation rate will be raised. Turning the knob
clockwise will raise the temperature and lower the
activation rate.
Fig. 11
Gas control slide button
The gas control slide button adjusts temperature by
adjusting how much gas is allowed to flow to the
burners.
As the slide is adjusted to the left, the output
temperature will lower, with the lowest setting being the
one flame position 0}. The hottest position is the three
flame position all the way to the right 0_.
8716473147 15