Dimensions 59.5 mm x 108 mm x 16 mm (2.19 in x 4.25 in x 0.629 in)
Voltage (operating) 12 VDC nominal
Current (maximum) 100 mA max
Connectors LAN/WAN: RJ-45 modular port (Ethernet)
Ethernet cable Category 5 or better unshielded twisted pair, 100 m (328 ft) max length
Interface IEEE 802.3
Data bus wire size 1.02 mm to 0.65 mm (18 AWG to 22 AWG)
Data bus wire length Maximum distance - Wire size:
150 m (500 ft) - 0.65 mm (22 AWG)
300 m (1000 ft) - 1.02 mm (18 AWG)
Web browser Microsoft Internet Explorer 6 or higher; Mozilla Firefox 3 or higher
Compatibility D9412, D7412, D7212, D9112
G Series Version 6.3 or higher
GV2 Series
GV3 Series
GV4 Series
B5512/B4512/B3512
8 | Specications
5 | LED descriptions
The B426 module includes the following on-board LEDs to assist
with troubleshooting issues (refer to Figure 1.1 for the location of the
LEDs):
– Heartbeat (system status). Refer to Table 5.1.
– Data Bus communication. Refer to Table 5.2
– Ethernet communication. Refer to Table 5.3.
Flash pattern Function
Flashes once
every 1 sec
Normal state: Indicates normal operation state.
3 quick ashes
every 1 sec
Communication error state: Indicates (the
module is in a “no communication state”)
resulting in an SDI2 communication error.
On Steady LED trouble state: Module is not powered
(for OFF Steady only), or some other
trouble condition prohibits the module from
controlling the heartbeat LED.
Off
Table 4.1: Heartbeat LED descriptions
Flash pattern Function
RX (Receive)
ashes
Occurs when the control panel bus receives a
message.
TX (Transmit)
ashes
Occurs when the control panel bus sends a
message.
Table 4.1: Data bus LEDs descriptions
LINK (yellow)
ash pattern
100mb (green)
ash pattern
Function
Off Off No Ethernet link
On Steady Off 10 BASE-T link
Flash Off 10 BASE-T activity
On Steady On Steady 100 BASE-T link
Flash On Steady 100 BASE-T activity
Table 4.1: Ethernet LINK and 100mb LEDs descriptions
7 | Certications
Region Certication Applicable control panels
US UL 365 – Police Station Connected Burglar Alarm Units and Systems B5512/B4512, GV4 Series, GV3 Series, GV2 Series
UL 609 – Local Burglar Alarm Units and Systems B5512/B4512, GV4 Series, GV3 Series, GV2 Series
UL 864 – Control Units and Accessories for Fire Alarm Systems
(Including NFPA 72)
GV4 Series, GV3 Series, GV2 Series, FPD-7024
UL 985 – Household Fire Warning System Units B5512/B4512, GV4 Series, GV3 Series, GV2 Series
UL 1023 – Household Burglar Alarm System Units B5512/B4512, GV4 Series, GV3 Series, GV2 Series
UL 1076 – Proprietary Burglar Alarm Units and Systems B5512/B4512, GV4 Series, GV3 Series, GV2 Series
UL 1610 – Central Station Burglar Alarm Units B5512/B4512, GV4 Series, GV3 Series, GV2 Series
FCC Part 15 Class B, NIST FIPS-197 AES Certication
(IP Communications)
B5512/B4512, GV4 Series, GV3 Series, GV2 Series, G Series,
DS7200, DS7400, Easy Series V3+, AMAX 2000
Canada CAN/ULC S303 - Local Burglar Alarm Units and Systems B5512/B4512, GV4 Series, GV3 Series, GV2 Series
CAN/ULC S304 - Signal Receiving Centre and Premise Alarm Control
Units
B5512/B4512, GV4 Series, GV3 Series, GV2 Series
ULC-ORD C1023 - Household Burglar Alarm System Units B5512/B4512, GV4 Series, GV3 Series, GV2 Series
ULC-ORD C1076 - Proprietary Burglar Alarm Units and
Systems
B5512/B4512, GV4 Series, GV3 Series, GV2 Series
ICES-003 - Digital Apparatus B5512/B4512, GV4 Series, GV3 Series, GV2 Series
When the tamper switch is activated (closed to open), the heartbeat
LED stays OFF for 3 sec before indicating the rmware version.
The LED pulses the major, minor, and micro digits of the rmware
version, with a 1 sec pause after each digit.
Flashing patterns do not start until the tamper is open (short is
removed). In the following is an example, the version 1.4.3 shows as
LED ashes:
[3 sec pause] *___****___*** [3 sec pause, then normal operation].
To show the rmware version using an LED ash pattern:
– If the optional tamper switch is installed:
With the enclosure door open, activate the tamper switch (push and
release the switch).
– If the optional tamper switch is NOT installed: Momentarily short
the tamper pins.
Refer to Figure 6.1 for an example of ash patterns.
6 | Show the rmware version
Figure 6.1: Firmware LED ash patterns
For complete installation, con guration, and testing instructions,
refer to the Conettix Ethernet Communication Module (B426)
Installation and Operation Guide provided on the supplied
CD-ROM.
en Installation Guide (UL)
Conettix Ethernet Communication
Module
B426