Maintenance5.
Cleaning5.1
The housing and the charger display may only be clea-
ned with a damp cloth and neutral cleaning agents. Do
not use abrasive cleaning agents or rough workshop
cleaning cloths.
Spare and wearing parts5.2
Description Order Number
Charging lead with PVC insulation
>)
1 684 460 235
Mains connecting lead
<)
1 684 460 236
<)
Wearing part
Disposal5.3
This BAT 415 is subject to European guide-
lines 2002/96/EG (WEEE).
Old electrical and electronic devices, including-
cables and accessories or batteries must be
disposed of separate to household waste.
Please use the return and collection sys- ¶
tems in place for disposal in your area.
Damage to the environment and hazards to ¶
personal health are prevented by properly
disposing of BAT 415.
Technical data6.
Properties Value, Range
Charging current Max. 15 A
Charging lead length
*)
2 m
Charging lead cross-section 4.0 mm
2
Power consumption 280 W
Weight approx. 4 kg
Characteristic charging curve IUIaIaI
Final charge volta-
ge at setting > 15 °C
14.0 V
Voltage limit for secondary
charging at setting > 15 °C
14.4 V
Final charge volta-
ge at setting < 15 °C
14.4 V
Voltage limit for secondary
charging at setting < 15 °C
14.8 V
Back up / buffer mode 12.0 V maximum 3 A
13.5 V maximum 15 A
Function temperature range 0 °C to 40 °C
Mains voltage / frequency 230 V, 50/60 Hz
Mains fuse H 250 T 3.15 A
Nominal battery voltage 12 V
Protection type (DIN 40050) IP 20
Class of protec-
tion (DIN 40530)
II
Dimensions (W x H x D) 260 x 160 x 250 mm
Work-related noise emis-
sion value (Lpa)
≤ 70 dB(A)
Interference emission level DIN 40839 Interfe-
rence emission level I
*)
The charging leads may not be changed!