EasyManua.ls Logo

Bosch CLL2000-Set 26 W I - User Manual

Bosch CLL2000-Set 26 W I
80 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
6721831695 (2021/02) div
ar ﺔﻠــــﺼﻔﻨﻣ ﺪــــﻳﺮﺒﺗ ةﺪــــﺣﻮﺑ ﻒــــﻴﻴﻜﺗ زﺎــــﻬﺟ ﺐـــــﻴﻛﺮﺘﻟا ﻞـــــﻴﻟد. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
az Split kondisioner Quraşdırma t ə limatı . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
en Split air conditioner Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
fr Climatiseur split Notice d’installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
ka სპლიტ ტიპის კონდიციონერი მონტაჟის ინსტრუქცია . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
pt Aparelho de ar condicionado Split Instruções de instalação . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
ru Сплит-система Инструкция по установке. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Climate Line 2000
0010032905-001
CLL2000-Set23W I CLL2000-Set26W I CLL2000-Set35W I CLL2000-Set53W I
CLL2000-Set70W

Table of Contents

Questions and Answers

  • L
    Lori GordonAug 10, 2025
    What to do if my Bosch CLL2000-Set 26 W I Air Conditioner outdoor or indoor unit is not working?
    • J
      Jessica WhiteAug 10, 2025
      If your Bosch Air Conditioner's outdoor or indoor unit isn't working, first check the power connection and ensure the indoor unit is powered on. Also, inspect the RCD (Residual Current Device) to see if it has tripped.
  • A
    Amber MartinezAug 20, 2025
    How to fix low output on my Bosch CLL2000-Set 26 W I indoor unit?
    • K
      Kyle SmithAug 20, 2025
      If your Bosch Air Conditioner's output is too low, it could be due to a soiled heat exchanger in either the outdoor or indoor unit. Clean the heat exchanger of the affected unit. Another possible cause is a lack of refrigerant. In this case, check the tightness of the pipes, reseal if necessary, and refill the refrigerant.
  • W
    wmilesAug 28, 2025
    Why does my Bosch Air Conditioner outdoor unit start and stop continuously?
    • B
      Brett FrankAug 29, 2025
      If your Bosch Air Conditioner's outdoor or indoor unit starts and stops continuously, it could be due to several reasons. It might be caused by insufficient refrigerant in the system, so you should check the tightness of the pipes, reseal if required, and refill the refrigerant. Alternatively, there might be too much refrigerant in the system, requiring you to remove refrigerant with a refrigerant recovery unit. Another possible cause is moisture or impurities in the refrigerant circuit, which means you need to evacuate the refrigerant circuit and fill it with new refrigerant. High voltage fluctuations can also cause this issue, and the solution is to install a voltage regulator. Lastly, a defective compressor could be the culprit, necessitating a compressor replacement.

Summary

Symbols and Safety Instructions

Explanation of Symbols

Defines warning symbols and their meanings for safety.

Installation

Unit Installation

Provides step-by-step instructions for physically mounting the indoor and outdoor units.

Pipework Connection

Guides the connection of refrigerant lines between the indoor and outdoor units.

Electrical Connection

Commissioning

Troubleshooting

Faults with Indication

Lists fault codes displayed by the unit and their potential causes.

Faults without Indication

Describes common errors and their corresponding remedies without error codes.