D7212G Approved Applications Compliance Guide
D7212G
Page 7© 2003 Bosch Security Systems 4998138560C
2.0 System Chart
Household Burglary
Household Fire
Household Fire/ Burglary
Combined
Central Station Burglary
(Grade C)
Police Connected
Burglary
Local Burglary
Minimum Hours of Standby
Battery
4
24 +
4
mins
alarm
24 +
4
mins
alarm
444
D8103 Enclosure
No No
D8108A Enclosure
Req. Req.
D8109 Enclosure
Choose one.
D101 lock required for
enclosure.
No No
D122 and D122L Dual Battery
Harness
Calculate current draw to determine if second
battery is required.
D125B Class B, Style A
Powered Loop Interface
Opt. # # Opt. Opt. Opt.
D129 Class A, Style D Initiating
Module
##
D126/D1218 Battery
1+ 1+ 1+ 1+ 1+ 1+
D127 Reversing Relay
Opt. No Opt. Opt. Opt. Opt.
D928 Dual Phone Line Module
Opt. Opt. Opt. Opt. Opt. Opt.
D161 Telephone Cord
Required to connect panel to RJ31X
TelCo. Block
D185 Auxiliary Interface Kit
D192A/D192C/D192G Class B,
Style W Bell Circuit Supervision
Opt. Opt. Opt. Opt. Opt. Opt.
Smoke Detector Base
1++ 1++
D268/D269H Independent Zone
Control
Optional,
only
connect to zones 1 to 8.
Indicating Device
1+ 1+ 1+ Opt. ** **
D461 Pull Station
Optional, may be required by job specifications
and/or Authority Having Jurisdiction.
D1255/D1260 Command Center
1+ 1+ 1+ 1+ 1+ 1+
D1256
Opt. Opt. Opt. Opt. Opt. Opt.
D1257
Opt. Opt. Opt. Opt. Opt. Opt.
D1640 Transformer
Required for
all
applications.
D8004 Transformer Enclosure
Opt. Opt. Opt. Opt. Opt. Opt.
D8122 Derived Channel S.T.U.
Optional, contact TelCo. for availability of derived
channel service.
D8125 Class B, Style 3.5
POPEX Module
Required for D8127T/U and D9127T/U POPITs.
D8125MUX
Required for MUX devices. Refer to section 4.2.
D8127T/U & D9127T/U Class B,
Style A POPIT Modules
Opt. Opt. Opt. Opt. Opt. Opt.
D8128D OctoPOPIT
Opt. No Opt. Opt. Opt. Opt.
D8129 OctoRelay
Optional, for remote annunciation of system
functions.
D8130 Release Module
Optional
D8132 Battery Charger
See Current Rating Chart and Standby Battery
Requirements to determine if system requires a
D8132 Module for increased battery standby.
D9131A Parallel Printer Interface
Optional, use with parallel printer to print events
from panel log locally.
No = Not acceptable for this application. Req. = Required for this application. Opt. = Optional for this application.
# - D125B and D129 required to connect fire alarm initiating devices to zones 1-8. D125B provides two powered loops for connecting listed
2-wire smoke detectors. D129 provides two non-powered Class A initiating circuits.
1+ = One or more required for this application. Consult the appropriate standard.
1++ = At least one detector required. You can substitute other 2-wire detectors listed for use with the D125. You could also use the D262
with the D270 4-wire base and a listed power supervision relay.
** = Listed bell (siren) housing required for burglary alarm bell or siren.
[Empty Cell] = Not used for this application.
Table 1: UL System Chart
System Chart