D9412GV2/D7412GV2 | Troubleshooting Guide | 3.0 Troubleshooting
20 Bosch Security Systems, Inc. | 11/05 | F01U011024B
Table 11: [COMMMAND][4][6] Display
Descriptions
Display Description
- Door not programmed in system.
F Communication failure between control panel
and D9210B.
Refer to TTP4 Keypad Shows
SERVICE 9210 on page 18.
A D9210B DIP Switch 5 is in OFF position. Set
to ON position.
If DIP Switch 5 is OK, refer to
TTP47 Open Wiring on page 100.
D
D9210B DIP Switch 6 is in OFF position. Set
to ON position.
If DIP Switch 6 is OK, refer to
TTP47 Open Wiring on page 100.
U Door is currently unlocked. To change state,
press the keypad number key that corresponds
with the door’s number. The number replaces
the “U” in the keypad display.
X Door is currently secured.
D1255 Keypad: Press [MENU/ESC]. Keypad
shows UNLOCK DOOR? Press [Next] until
keypad shows SECURE DOOR? Press [ENT].
To change state, press the keypad number key
that corresponds with the door’s number. The
number replaces the “X” in the keypad display.
D1260 Keypad: Press [Exit]. Press [SECURE
DOOR?]. To change state, press the keypad
number key that corresponds with the door’s
number, then press [ENTER]. The number
replaces the “X” in the keypad display.
Number Door is currently locked.
Figure 12: [COMMAND][4][6] Display
Control Panel
D9210B
for Door #2*
Door #2 Door #3
UNLOCK: 1 2 F 4 - - - -
Keypad Display
1
PWR +
7
SDIB
6
SDIA
5
COM
8
T +
10
ZN +
9
ZNCOM
2
LCKN/C
3
LCKCOM
4
LCKN/O
13
REX
12
COM
11
RTE
16
DATA 1
17
BUZZER
18
LED
15
DATA 0
14
+5.20V
D0
READER
OPER
MON
1
2
3
4
5
6
ON
D9210B
for Door #3*
1
PWR +
7
SDIB
6
SDIA
5
COM
8
T +
10
ZN +
9
ZNCOM
2
LCKN/C
3
LCKCOM
4
LCKN/O
13
REX
12
COM
11
RTE
16
DATA 1
17
BUZZER
18
LED
15
DATA 0
14
+5.20V
D0
READER
OPER
MON
1
2
3
4
5
6
ON
* D9210B DIP switch address = door number
Figure 13: Swap D9210B DIP Switch Addresses
Control Panel
D9210B
for Door #3
Door #3 Door #2
1
PWR +
7
SDIB
6
SDIA
5
COM
8
T +
10
ZN +
9
ZNCOM
2
LCKN/C
3
LCKCOM
4
LCKN/O
13
REX
12
COM
11
RTE
16
DATA 1
17
BUZZER
18
LED
15
DATA 0
14
+5.20V
D0
READER
OPER
MON
1
2
3
4
5
6
ON
D9210B
for Door #2
1
PWR +
7
SDIB
6
SDIA
5
COM
8
T +
10
ZN +
9
ZNCOM
2
LCKN/C
3
LCKCOM
4
LCKN/O
13
REX
12
COM
11
RTE
16
DATA 1
17
BUZZER
18
LED
15
DATA 0
14
+5.20V
D0
READER
OPER
MON
1
2
3
4
5
6
ON
Swap DIP switch addresses.
By swapping DIP switch addresses, Door #2
becomes Door #3, and vice-versa.