D9412GV2/D7412GV2
D9412GV2/D7412GV2 Release Notes for Version 7.09
© 2013 Bosch Security Systems, Inc. Page 11 F01U003637-06
Cancel Window
Prompt:
CC# Cancel Display
The burglary alarm cancel window is enhanced
by an optional keypad display. When
CC# Cancel
Display
is set to Yes and
Cancel Report
is set to
Yes, an alarm silence operation after event
transmission displays CANCEL RPT SENT on the
keypad. The burglary alarm cancel window
duration is the time programmed in the
A# Alarm
Bell
prompt.
Prompts:
Duress Type
,
A# Duress Enable
,
L##
Send Duress
A new duress option is available that allows any
passcode with the
L# Send Duress
permission
set to
Yes to always send a Duress Alarm event
upon entry. This feature allows the control panel
to have uniquely dedicated passcodes for all
users. Additionally, when this feature is enabled,
the Passcode +1 and +2 features are disabled for
compliance with SIA CP-01-2000 regulations.
Swinger Shunt Enhancement
Prompt:
Swinger Count
The Swinger Bypass feature is enhanced to allow
a variable number of faults before automatically
bypassing a point. When a point with
P# Swinger
Bypass
set to Yes is faulted the number of times
programmed in
Swinger Bypass Count
, it is
automatically bypassed.
Power-Up Standby
When the control panel is powered up, or the
system is rebooted, all points are temporarily
bypassed for 60 seconds. This feature is always
enabled and has no configuration parameters.
Walk Test Enhancements
The Walk Test procedure is enhanced to provide
more user feedback. The Walk Test now indicates
that the menu is ready to time out, and clearly
notifies the user at all keypads in the area of
operation when a test is in progress.
Additionally, the Walk Test procedure issues
point trouble conditions for any 24-hour or fire
points that remain off-normal when the Walk Test
menu exits. After the system annunciates the
trouble condition, faulted points are
automatically swinger shunt bypassed regardless
of the point index settings. These enhancements
are always enabled and have no configuration
parameters.
2.7 Version 7.03
• Changes allow Custom Functions to operate
correctly in the Function List when
CC# Menu
Lock
is set to Yes on the D1260 and D1260B
Keypads.
• Corrections disassociate the
L# Display
Revision
authority level from the Service
Menu on the D1260 and D1260B Keypads.
• Corrections ensure that the authority level
permissions of each
L# Custom Function ###
are strictly associated with the correct
Custom Function number.
• If
Expanded Test Report
is set to Yes,
Summary Fire Supervision, Summary Fire
Fault, Summary Control Point Fault and
Summary Point Device are now included
when a test report is sent using COMMAND
41 or a sked.
• Corrections enhance the reliability and
performance of RPS network connection.
These corrections also decrease the delay in
reporting a break in the Ethernet connection
to the control panel’s Network Interface
Module within the time limits required by UL.
• For UL 1610 Line Security (formerly Grade
AA) Intrusion System installations and for UL
864 Commercial Fire installations, use the
parameters shown in Table 4 when
configuring the Heartbeat Poll. For additional
details, refer to Programming Path Numbers
and IP Addresses for Enhanced
Communications in the D9412GV2/D7412GV2
Program Entry Guide (P/N: F01U003636).
The recommended settings in Table 4
(Poll Rate of 75) enable the control
panel to annunciate locally, within
200 seconds, any break in the
network communication path.