D9412GV2/D7412GV2
D9412GV2/D7412GV2 Release Notes for Version 7.09
© 2013 Bosch Security Systems, Inc. Page 7 F01U003637-06
2.5 Version 7.05
Version 7.04 was skipped during
development and was not released.
The default values for the
Path # ACK Wait
Time
and
Path # RetryCount
configuration
parameters in Version 7.05 firmware are
sufficient to meet UL 864 requirements.
Changes reset the User Code Tamper
condition when it is reported to the central
station in an Expanded Test Report.
Changes ensure that the keypad emits a tone
when a point is activated during a Walk Test.
Changes prevent the ALARM SILENCED
message from showing on the keypads when
the Silent Alarm bell timer expires. This
corrects the problem described in the GV2
Series Control Panels Invisible Points Technical
Service Note (P/N: F01U032203).
When a Route Group is configured with an IP
destination in the primary path and a
telephone number in the backup path, a
break in the Network Link Integrity now
annunciates locally.
Changes ensure that the D928 primary and
secondary phone line failure LEDs operate
only when the Phone Supervision interval is
enabled.
Corrections improve the reliability of the
direct connection communication method
between the control panel and RPS through a
D5360.
Corrections prevent a programmed # symbol
from being dialed as a zero (0).
If multiple areas use the same relay for the
A#
Perimeter Armed
area-wide relay function,
the relay activates when all areas are
perimeter armed. The relay deactivates when
the first area disarms.
The sensitivity of the Ground Fault feature is
modified to be equivalent with Version 6.90
and to prevent false reports.
The authority scope problem with the Menu
Key Lock feature, described in the GV2 Series
Control Panels Menu Key Lock Technical
Service Note (P/N: F01U032240B), is
corrected.
When a user changes the time and date in the
control panel, the corresponding event now
reports consistently the identification of the
user who made the change.
Event reporting for a relay that is set or reset
using the RPS Diagnostics screen is changed
to indicate that the operation was done By
Programmerinstead of By Remote”. For
example, setting a relay with RPS now sends
a Relay Set by Programmer at SDI 88 event.
Corrections improve the user interface for
the Door Control sub-menu (CMD 46) in the
D1260 and D1260B Keypads.
Changes now require users to have an
L#
Door Control
authority level to enter the
Door Control menu. Formerly, only the
L#
Cycle Door
authority was required.
Corrections to the Door Control menu
(COMMAND 46) for the D1260 and D1260B
Keypads restrict the menu items based on
the
L#
Cycle Door
,
L#
Unlock Door
and
L#
Secure Door
settings.
Minor corrections improve the user interface
for the following function list menus on the
D1260 and D1260B Keypads:
Master Arm?
Master Arm Instant?
Perimeter Arm Delay?
Perimeter Arm Inst?
Disarm?