D9412GV2/D7412GV2 Release Notes for Version 7.09
F01U003637-06 Page 4 © 201313 Bosch Security Systems, Inc.
when performing the following arming
commands: Master Delay (COMMAND 1),
Master Instant (COMMAND 11), Perimeter
Instant (COMMAND 2), Perimeter Delay
(COMMAND 3), and Perimeter Partial
(COMMAND 8). This acknowledgement
screen is for the Passcode Arm command
only.
Bosch Security Systems, Inc. does not
recommend setting
A# Master Arm No Exit
to
Yes in an area that has A# Area Type set
to
Associate or Master. Coexistence of these
two features is supported, but might result in
a shared area being left unintentionally
disarmed.
Corrections were made to the RPS Callback
via Network feature in GV2 firmware V7.07
and later. This feature is best supported by
RPS v5.10 and later.
Corrections were made to the RPS Connect
via Network (COMMAND 43) feature in GV2
firmware V7.07 and later. This feature is best
supported by RPS v5.10 and later.
Corrections were made to ensure the Clear
Display prompt is shown on the D1260 or
D1260B keypad after an alarm is silenced by
disarming with a key-switch.
The Change Relay function (COMMAND 54) is
modified to work with the on-board points.
Use the following relay numbers to toggle the
on-board relays:
On-Board Relay
Relay
Number
Mapped
Relay
Number*
A (terminal 6) 253 250
B (terminal 7) 254 251
C (terminal 8) 255 252
*Remote systems identify the on-board
relays by different numbers, so those values
automatically map to the local values.
Improvements were made to the Secure Door
and Unlock Door commands to show current
door status in a more consistent manner.
Previously, the Secure Door or Unlock Door
status was momentarily defaulting to the
door number on the keypad display.
2.3 Version 7.07
The following corrections and changes were
made in the GV2 Series Control Panels since
Firmware 7.06:
The RPS port number prompt was renamed
and moved from
GV2AUX
SDIRPS/ENHANCED CONF
BasePortNumber to GV2AUX SDI RPS
PARAMETERS RPS Port Number in
GV2AUX v1.03.
The Anti-Replay enable prompt for the Anti-
Substitution feature was renamed and moved
from
GV2AUX MISCELLANEOUS
EnableAntireplay to GV2AUX ENHANCED
COMM Path #AntiReplay in GV2AUX
v1.03. The value in the
EnableAntireplay
prompt when using GV2AUX v1.02 or older
shows in the
Path 1 Anti-Replay
prompt.
When you upgrade a D9412GV2 or
D7412GV2 with firmware version 7.07
or later, you must enable the Anti-
Replay option individually for each
enhanced communication path if you
are using this feature. Previously, one
prompt applied to all destination
paths.
Changes made improve the reliability of the
Time Sync feature. When enabled, this
feature no longer causes intermittent
erroneous skipping or duplication of skeds.
This corrects the issues described in the G-
GV2 Series Skeds Technical Bulletin (P/N: TBI
10-5-06 1 B).
For optimal keypad user interface
performance, ensure that any D1260 or
D1260B Keypads connected to the system
are running firmware version 1.04 or later. An
update kit (P/N: R19-D1260-0104) is available
from Customer Service: (800) 289-0096.
Changes made prevent the recent close alarm
feature from interfering with panic alarm
reports. Now, a panic alarm (an alarm
generated by a 24-hour point) is reported as
a Burglar Alarm in any arming state. This
corrects the issue described in the SIA CP-01
and Panic Alarms Technical Bulletin (P/N:
F01U064901-01).
Changes made prevent corrupted account
codes for systems that communicate with BIS
2.0 Security Engine. These changes are only