EasyManua.ls Logo

Bosch DIP-7080-00N - Multiple Disks Failed - Practice

Bosch DIP-7080-00N
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Event Data:
===========
Target Id: 1
Useful commands:
MegaCli -AdpEventLog -GetEvents -info -f info.txt -aALL
(but a large text file)
MegaCli -AdpEventLog -GetEvents -fatal -f fatal.txt -aALL
Adapter: 0 - Number of Events : 288
seqNum: 0x0000188f
Time: Mon Jul 19 13:52:41 2010
Code: 0x000000fc
Class: 3
Locale: 0x01
Event Description: VD 00/0 is now OFFLINE
Event Data:
===========
Target Id: 0
Adapter: 0 - Number of Events : 288
seqNum: 0x00001891
Time: Mon Jul 19 13:52:41 2010
Code: 0x000000fc
Class: 3
Locale: 0x01
Event Description: VD 01/1 is now OFFLINE
Event Data:
===========
Target Id: 1
Multiple disks failed – practice
Press "C" to enter Utility. Click "start" and "scan disks".
You get to the "foreign configuration import" screen.
7.2.2
42 en | Recovering the unit DIVAR IP 7000 2U
2014.12 | V4 | DOC Installation Manual Bosch Sicherheitssysteme GmbH

Table of Contents

Other manuals for Bosch DIP-7080-00N