12. Connect the DIVAR to an approved ground point. Use the ground screw (supplied in the
accessory bag) to attach a ground cable to the DIVARback panel ground point .
Back panel connectors DIVAR network 2000/3000 (no PoE)
RJ45 video input for max. 32 IP cameras (max. 16 IP cameras
for DIVAR 2000) connected via external switch (optional with
DHCP configuration)
RJ45 Ethernet connection (10/100/1000Base-T according to
IEEE802.3)
1 D-SUB (Monitor output)
1 HDMI (Monitor output)
4 screw terminal inputs, cable diameter AWG26‑16 (0.13–
1.5 mm)
2 screw terminal outputs, cable diameter AWG26‑16 (0.13–
1.5 mm)
1 RCA (Audio output)
1 RCA (Audio input)
Screw terminal output
DB9 male, 9-pin D-type
One USB (3.0) connector for mouse or USB memory device;
one USB (2.0) also on front panel
Power input with On/Off
switch
12 VDC (5 A)
AC input adapter: 100~240 VAC, 50-60 Hz, 1.5 A
Ground connection
5.1.1
DIVAR 2000 / DIVAR 3000 / DIVAR
5000
Safety | en 9
Bosch Security Systems Installation Manual 2016.08 | v1.0 | AM18-Q0712