DIVAR IP 7000 (2U) Safety information | en 7
Bosch Sicherheitssysteme GmbH Installation Manual 2016.07 | V2 | DOC
Do not install device near any heat sources such as radiators, heaters, stoves, or other
equipment (including amplifiers) that produce heat.
Never spill liquid of any kind on the device.
Take precautions to protect the device from power and lightning surges.
Unless qualified, do not attempt to service a damaged device yourself. Refer all servicing
to qualified service personnel.
Install in accordance with the manufacturer's instructions in accordance with applicable
local codes.
Use only attachments/accessories specified by the manufacturer.
Protect all connection cables from possible damage, particularly at connection points.
Do not defeat the safety purpose of a polarized or ground‑type plug.
Permanently connected devices must have an external, readily operable mains plug or
all‑pole mains switch in accordance with installation rules.
Pluggable devices must have an easily accessible socket-outlet installed near the
equipment.
Unplug the unit from the outlet before cleaning. Follow any instructions provided with the
unit.
Any openings in the unit enclosure are provided for ventilation to prevent overheating and
ensure reliable operation. Do not block or cover these openings.
Do not place the unit in an enclosure unless proper ventilation is provided, or the
manufacturer's instructions have been adhered to.
Install the unit only in a dry, weather-protected location.
Do not use this unit near water, for example near a bathtub, washbowl, sink, laundry
basket, in a damp or wet basement, near a swimming pool, in an outdoor installation, or
in any area classified as a wet location.
To reduce the risk of fire or electrical shock, do not expose this unit to rain or moisture.
Never push objects of any kind into this unit through openings as they may touch
dangerous voltage points or short-out parts that could result in a fire or electrical shock.
Power supply cords should be routed so that they are not likely to be walked on or
pinched by items placed upon or against them, playing particular attention to cords and
plugs, convenience receptacles, and the point where they exit from the appliance.
Operate the unit only from the type of power source indicated on the label. Use only the
power supply provided or power supply units with UL approval and a power output
according to LPS or NEC Class 2.
Do not open or remove the cover to service this unit yourself. Opening or removing covers
may expose you to dangerous voltage or other hazards. Refer all servicing to qualified
service personnel.
Be sure the service technician uses replacement parts specified by the manufacturer.
Unauthorized substitutions could void the warranty and cause fire, electrical shock, or
other hazards.
Safety checks should be performed upon completion of service or repairs to the unit to
ensure proper operating condition.
Observe the relevant electrical engineering regulations.
When installing in a switch cabinet, ensure that the unit and the power supply units have
sufficient grounding.
Connect the unit to an earthed mains socket.
Use proper CMOS/MOS-FET handling precautions to avoid electrostatic discharge (ESD).
For protection of the device, the branch circuit protection must be secured with a
maximum fuse rating of 16A. This must be in accordance with NEC800 (CEC Section 60).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch DIVAR IP 7000 and is the answer not in the manual?

Bosch DIVAR IP 7000 Specifications

General IconGeneral
Microphone inYes
USB 2.0 ports quantity4
Ethernet LAN (RJ-45) ports3
USB 3.2 Gen 1 (3.1 Gen 1) Type-A ports quantity2
USB 3.2 Gen 1 (3.1 Gen 1) Type-C ports quantity0
Wi-FiNo
Ethernet LAN data rates10, 100, 1000 Mbit/s
RAID levels5, 6
Storage drive size3.5 \
Storage drive capacity120 GB
Storage drive interface-
Installed storage drive typeSSD
Supported storage drive typesHDD & SSD
Total installed storage capacity0.24 TB
Number of storage drives supported10
Bus typeQPI
SteppingC0
Scalability1S
Processor codeSR14S
Processor cache8 MB
Processor modelE3-1275V3
System bus rate- GT/s
Processor seriesIntel Xeon E3-1200 v3
Processor socketLGA 1150 (Socket H3)
Processor threads8
Processor codenameHaswell
Processor frequency3.5 GHz
Processor cache typeSmart Cache
Processor lithography22 nm
Processor manufacturerIntel
Processor package size37.5 x 37.5 mm
Processor front side bus- MHz
PCI Express slots version3.0
Processor boost frequency3.9 GHz
Processor operating modes64-bit
PCI Express configurations1x16, 2x8, 1x8+2x4
Thermal Design Power (TDP)84 W
On-board graphics card modelIntel® HD Graphics P4600
Memory bandwidth supported by processor (max)25.6 GB/s
Maximum internal memory supported by processor32 GB
Internal memory8 GB
Memory clock speed1666 MHz
Internal memory typeDDR3
Thermal solution specificationPCG 2013D
Maximum number of PCI Express lanes16
Memory types supported by processorDDR3-SDRAM
Memory channels supported by processorDual
Intel Identity Protection Technology version1.00
Chassis typeRack (2U)
Cooling typeActive
Product colorBlack
Number of fans2 fan(s)
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Power supply unit (PSU) capacity740 W
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)8 - 90 %
TypeStorage server
Optical drive typeDVD-RW
Operating system installedWindows Storage Server 2012 R2
On-board graphics card base frequency350 MHz
On-board graphics card dynamic frequency (max)1250 MHz
CertificationCE, UL
Processor ARK ID75464
Weight and Dimensions IconWeight and Dimensions
Depth648 mm
Width437 mm
Height89 mm