EasyManua.ls Logo

Bosch Greentherm T9800 SEO199 - Manual Gas;Air Flow Adjustment

Bosch Greentherm T9800 SEO199
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Greentherm T9800 SEO 160/199 | SECO 199 – 6 720 817 281 (2018/12)
40
Open hot water taps when the display shows Tap Symbol
image (1 tub and 2 sinks should be sufficient; when there is
enough water flow the image disappears).
Fig. 39 Combustion Auto Adjust - Open Taps
The Combustion Auto Adjust process takes several minutes.
Steps from 1 to 7 will appear on the display.
Do not interfere with the appliance during the auto
adjustment process.
Wait until display shows dn blinking as a sign of calibration
complete.
Touch the symbol to exit UC menu.
Gas and Air auto adjustment is complete.
In case of failure in the auto calibration process the error sign
appears.
Verify if:
Appears any error codes on the display, see table 20.
Gas type and pressure are correct.
Wind conditions are stable (e.g. wind gusts may be a cause
of failure).
Hot water flow is sufficient and stable (e.g. water from a
well is a potential source of water instability).
In case of positive results for all these actions:
Exit UC menu and repeat the process.
If failure persists:
Perform manual adjustment according to chapter 8.11.2
or contact Bosch support line for further assistance.
8.11.2 Manual adjust Gas/Air flow
Gas/Air flow adjust is also possible to perform manually (only
recommendable if automatic adjust is not possible to conclude
successfully).
First step - Adjust the maximum power (P1)
Press the button to turn ON.
Press and hold simultaneously buttons , and
for 3 seconds, until display reads P4.
Fig. 40
Press the buttons or to select P1 (Maximum
Power) menu.
Open hot water taps when the display shows Tap Symbol
image (1 tub and 2 sinks should be sufficient; when there is
enough water flow the image disappears).
Press to enter P1 adjustment.
Display shows E.
Press or until L1 appears.
Press the button to enter L1.
Display shows L1 value.
Verify if power bar level is at middle point, see fig. 41.
Fig. 41 Power bar middle point