Bosch Power Tools 1 609 929 V05 | (9.3.10)
Noise Information
Measured sound values determined according
to EN 61029.
Typically the A-weighted sound pressure level of
the product is 72 dB(A). Uncertainty K=3 dB.
The noise level when working can exceed
80 dB(A).
Wear hearing protection!
Declaration of Conformity
We declare under our sole responsibility that
the product described under “Technical Data” is
in conformity with the following standards or
standardization documents: EN 61029 accord-
ing to the provisions of the directives
2004/108/EC, 2006/42/EC.
Technical file at:
Robert Bosch GmbH, PT/ESC,
D-70745 Leinfelden-Echterdingen
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
26.01.2010
Technical Data
Dr. Egbert Schneider
Senior Vice President
Engineering
Dr. Eckerhard Strötgen
Head of Product
Certification
Double bench grinder GSM 175
Professional
GSM 200
Professional
GSM 200 D
Professional
Article number
0 601 277 0.. 0 601 277 1.. 0 601 277 2..
Rated power input P
1
W 500 700 550
Output power P
2
W 360 500 400
Operating Mode *
S2 (60 min.) S2 (60 min.) S2 (60 min.)
No-load speed
min
-1
2840 2800 2840
Thread of grinder spindle
M 10 M 10 M 10
Grinding wheels
–Diameter
–Width
–Mounting bore
Grain size
mm
mm
mm
175
25
32
36/60
200
25
32
36/60
200
25
32
36/60
Weight according to EPTA-Procedure
01/2003
kg 14.3 16.2 15.6
Protection class
/I /I /I
The values given are valid for nominal voltages [U] of 230/240 V. For lower voltage and models for specific countries,
these values can vary.
Please observe the article number on the type plate of your machine. The trade names of the individual machines
may vary.
* The operating mode S2 (60 min.) designates short-time operation with a maximum operating duration of 60 min-
utes. After this period, switch off the machine and allow it to cool down.
OBJ_BUCH-1114-001.book Page 17 Tuesday, March 9, 2010 1:07 PM