Required
Clearance
These
instructions
were
determined
using
standard
American
cabinets.
Standard
base
cabinets
measure
36"
(914
mm)
high
x
25"
(635
mm)
deep.
Cabinets
over
the
cooking
surface
and
cabinets
adjacent
to
those
over
the
cooking
surface
measure
13"
(330
mm)
deep
from
backwall.
If
nonstandard
cabinets
are
used,
care
should
be
taken
to
alter
dimensions
accordingly.
A
WARNING
To
eliminate
the
risk
of
burns
or
fire
by
reaching
over
heated
surface
units,
cabinet
storage
space
located
above
the
surface
units
should
be
avoided.
If
cabinet
storage
is
to
be
provided,
the
risk
can
be
reduced
by
installing
a
hood
that
projects
horizontally
a
minimum
of
5"
(127
mm)
beyond
the
bottom
of
the
cabinet.
From
cooktop
to
materials
above:
*
Minimum
clearance
of
36”
(914
mm)
for
gas
SIR,
30”
(762
mm)
for
Dual
Fuel
SIR,
is
required
to
an
overhead
combustible
surface.
*
Bosch
recommends
the
minimum
clearances
shown
in
the
installation
diagrams
contained
in
this
manual.
Clearances
from
non-combustible
materials
are
not
part
of
ANSI
Z21.1
scope
and
are
not
certified
by
CSA.
Clearances
less
than
shown
in
the
installation
diagrams
must
be
approved
by
local
codes
and/or
by
the
local
authority
having
jurisdiction
.
From
the
cooking
surface
to
side
materials:
No
clearance
is
required
from
unit
walls
to
adjacent
vertical
combustible
walls
on
rear,
right,
or
left.
English
8
Note:
Some
cabinet
finishes
cannot
survive
the
temperatures
allowed
by
safety
standards,
particularly
self-
cleaning
ovens;
the
cabinets
may
discolor
or
stain.
This
is
most
noticeable
with
laminated
cabinets.
measurements
in
inches
(mm)
*
XX
Minimum
clearance
of
36"
(914
mm)
for
gas
SIR,
30”
(762
mm)
for
dual
fuel
SIR,
required
to
overhead
combustible
surface.
If
installing
overhead
vent
or
over-the
range
microwave,
refer
to
clearances
provided
with
these
products.
**
Minimum
clearance
of
10"
required
from
cutout
to
combustible
side
walls.
Flame
retardant
materials
bear
the
mark:
UNDERWRITERS
LABORATORIES
INC.
CLASSIFIED
MINERAL
AND
FIBER
BOARDS
SURFACE
BURNING
CHARACTERISTICS,
followed
by
the
flame
spread
and
smoke
ratings.
These
designations
are
shown
as
“FHC
(Flame
Spread/Smoke
Developed)*.
Materials
with
“O”
flame
spread
ratings
are
flame-retardant.
Local
codes
may
allow
other
flame
spread
ratings.
It
is
the
responsibility
of
the
installer
to
ensure
installation
is
in
accordance
with
these
ratings.
9000989333
Rev
D